Whenever metal is detected, the Red Alert Light will illuminate.
Interference Elimination Button—
The detector is factory set for maximum sensitivity to detect
the smallest of items. This high level of sensitivity may produce alarms when approaching a floor
containing rebar. Press and hold this button to decrease sensitivity to a level that does not respond to
the rebar. Release the button and the detector returns to normal sensitivity.
Earphone/Recharger Jack—
An earphone is available (see Accessories) for "silent" operation or
for use in noisy environments. The rechargeable NiMH battery is also recharged through this jack.
Do not attempt to recharge conventional batteries. Attempting this will damage the detector. (See
Accessories for Rechargeable Battery Kit.)
Internal Threshold Adjust—
Adjustment is used to decrease sensitivity to surrounding material.
Adjustments should only be made by a supervisor who is authorized to set sensitivity levels. Turn
counter-clockwise to decrease sensitivity, clockwise to increase.
Safety Sling—
Used to assist the operator in convenient handling of the Super Scanner™ V.
Battery Cover—
Remains securely in place at all times but can be easily opened for changing the bat-
tery with no tools required.
OPERATING INSTRUCTIONS
Turn the detector on by setting the Power Switch to the On position. The Green Alert Light will illu-
minate and the Audio Alert will sound to indicate the unit has been turned On. The Green Alert Light
will remain on until the unit is turned Off.
When the Super Scanner™ V is operating, it will detect metal only while it is in motion. Move the
instrument within approximately two inches from the person (object) being inspected. Sound will
increase sharply and the Red Alert Light will illuminate whenever metal is detected adjacent to the
Scan Area. Operation is completely automatic. All conductive metals will be detected, including fer-