Siqura XCU-F Скачать руководство пользователя страница 2

 

XCU Installation manual supplement - 

Cables and connectors

 

 

Doc. ID:  XCU Installation manual supplement - Safety, cables and connectors v5.docx 
Authors: Wouter Hermelink, Peter de Konink  

 

 

 

 

 

 

 

 

 

 

Page 2/5

 

 

 
 

 

Install the unit 

 

 

Make sure that the installation surface can support at least four times the weight of 

the unit in normal operating conditions. In case of excessive external stress 

(vibration, strong winds or impact, for example), the equipment may need additional 

means of protection.

 

 

 

Proper stainless-steel hardware (grade A4 or 316) should be carefully chosen to 

fasten the unit

’s brackets to the surfaces. Use a suitable lubricant with (for example 

Molykote P-40) between threaded connections to avoid fretting corrosion. Proper 

tools should be used during the installation, in accordance to environmental 

requirements. 

 

 

 

Covers should be opened only by the manufacturer.

 

 

 

Electrical connections (such as plugs and cords) must be protected from potential 

hazardous environmental factors (e.g. foot traffic, hitting objects).

 

 

 

Pointing the camera at the sun may damage it.

 

 

 

In case the camera is mounted outdoors, exposed to the heating effects of the sun, the 
XCU camera sunshield must be used. 

 

 

Complete the installation performing the camera connection referring to the manual 

of the camera.

 

 
 
 
 
 
 
 
 

 

 
 
 

 

Carefully check the supply voltage marked on the label. An incorrect power supply 

voltage may damage the unit. Do not overload the terminal connection, as it may 
cause a fire or electrical shock hazard.

 

 

 

For 120 Vac / 230 Vac models: An all-pole mains switch with an opening distance 

between the contacts at least 3 mm in each pole must be incorporated in the electrical 

installation. The switch must be equipped with protection against the fault current 

towards the ground (differential) and the overcurrent (magnetothermal, maximum 10 A).  

 

Recommended for 120 Vac / 230 Vac

: 2 A Delayed Fuse T (Time delay) or equivalent 

resettable devices such as magnetothermal. 

 

Recommended for 24 Vac:

 4 A Delayed Fuse T (Time delay) or equivalent resettable 

devices such as magnetothermal.  

These ratings include inrush current for startup or temporary overload. It must be very 

quickly recognisable and readily accessible. Install a suitable overcurrent protection, 

maximum 10 A. 

 

 

Make sure that the unit case is properly earthed. The Protective Earth (PE) connection 

is included in the 3p or 5p power connector. The minimum wire size is 0.75 mm

2

 copper 

stranded wire.

 

 

 

 

 