1.4
Install the camera
● Prior to installation and operation, carefully read all instructions in this manual
and heed all warnings.
● Unpack this equipment and handle it carefully. If the package appears to be
damaged, notify the shipper immediately.
● Use the original packaging to transport the unit.
● Make sure that the installation surface can support at least four times the
weight of the unit in normal operating conditions. In case of excessive
external stress (e.g. vibration, strong winds or impact), the equipment may
need additional means of protection.
● Use 316L stainless steel hardware to fasten the unit to the surfaces.
● Use caution when lifting and assembling the unit. It is recommended that
non-slip protective gloves be worn during installation. The unit could bear
sharp edges.
● Trying to manually force the wiper will result in damaging the device and will
void the warranty.
● To maintain the IP rating of the unit, correct cable glands must be used. The
unit must be tightly closed when operating.
● Open only the covers pointed out in this installation manual. Other covers
should be opened only by the manufacturer.
● This equipment has been designed to fit in harsh environments requiring little
or no maintenance. Suggested inspection interval is 6 months, but extremely
harsh environments may require more frequent inspection and maintenance
checks. On each inspection check the O-ring seals and the eventual window
wiper blade integrity. Replace them if necessary. Check cables, electrical
connections and mounting hardware for integrity and tightness. Replace or
tighten any damaged/loose part.
● Operating temperature: -20 °C to +60 °C (-4 °F to +167 °F); +75 °C
(+167°F) peak.
● Before dismounting or opening the unit, turn off the power. The installation of
the unit can be performed only by qualified personnel in accordance with the
regulations in force. Do not connect the unit to a supply circuit unless the
installation is completed.
● Carefully check the supply voltage marked on the label. Incorrect power
supply voltage may damage the unit. Do not overload the terminal
connection.
● An all-pole mains switch with an opening distance between the contacts at
least 3 mm in each pole must be incorporated in the electrical installation. The
switch must be equipped with protection against the fault current towards the
ground (differential) and the overcurrent (magnetothermal, maximum 15 A).
It must be very quickly recognisable and readily accessible. Install a suitable
overcurrent protection.
● For connection to the mains, use a multipolar cable having minimum 3x1,5
mm
2
(15 AWG). The main cable must be protected.
● Fasten all the cables inside the housing with cables ties or other fixing means
to avoid the electrical contact with surrounding parts in case cables get loose.
SA Fixed Series - Installation manual
5