Sipura SPA-2002 Configuration Guide
Page 4
3. Configuration
3.1 Configuration for Outbound Calling
To configure the SPA-2002 for outbound calling:
1. Connect to the SPA-2002 by entering the device’s IP address in the Web
browser’s Address bar. For instructions on obtaining the IP address, refer to
section 2.0 Accessing the SPA-2002 in Section 2.0 of this Guide.
2. Click on the Admin Login link in the upper right corner of the page, and then
click the advanced configuration link.
SPA-2002 Web Interface – Main Window
3. Click
the
Line1 or Line2 tab at the top of the page, and in the NAT Settings
section, change the following setting:
Field
Value
NAT Keep Alive Enable
no
4. In
the
Proxy and Registration section (see the screen on the following page),
change the following settings:
Field
Value
Proxy
byod1.net2phone.com
Use Outbound Proxy
no
Use OB Proxy In Dialog
no
Make Call Without Reg
yes
Ans Call Without Reg
yes
DNS SRV Auto Prefix
no
5. In
the
Subscriber Information section (as shown in the Line1/2 Window screen on
the following page), enter a Display Name. Enter the following values for
outbound only service:
Service Type
Field
Display Name
Value
Display Name (Line 1)
NO_DID1
OUTBOUND SERVICE ONLY
Display Name (Line 2)
NO_DID2
6. Enter
the
User ID (account) and Password (PIN).