23 

Declaration of Conformity 

 

We 

 

SIP (Industrial Products) Ltd 

Gelders Hall Road 

Shepshed 

Loughborough 

Leicestershire 

LE12 9NH 

England 

 

As the manufacturer's authorised representative within the EC 

declare that the 

 

Sub 1010FS Water pump - SIP Part No. 06879 
Sub 1015FS Water pump - SIP Part No. 06881 
Sub 1025SS Water pump - SIP Part No. 06885 

 

 

Conforms to the requirements of the following directive(s), as indicated.

 

 

 

 

2006/95/EC   

Low Voltage Directive 

 

 

 

2004/108/EC  

EMC Directive 

 

 

 

2002/95/EC   

RoHS Directive 

And the relevant harmonised standard/s, including: 

 

 

EN 55014-1+A2:2011 

EN 55014-2:+A2:2008 

EN 61000-3-2+A2:2009 

EN 61000-3-3:2008 

Signed: …………………………………... 

Mr P. Ippaso - Managing Director - SIP (Industrial Products) Ltd 
Date: 26/03/2013. 

  DECLARATION OF CONFORMITY 

Содержание SUB1010FS, SUB1015FS

Страница 1: ...ckaging to the local amenity tip and place into the appropriate recycling bin Never dispose of electrical equipment or batteries in with your domestic waste If your supplier offers a disposal facility...

Страница 2: ...FS Water pump SIP Part No 06881 Sub 1025SS Water pump SIP Part No 06885 Conforms to the requirements of the following directive s as indicated 2006 95 EC Low Voltage Directive 2004 108 EC EMC Directiv...

Страница 3: ...al Specifications 10 Contents Accessories 11 Getting to Know Your Water pump 12 Operating Instructions 14 Maintenance Instructions 15 Troubleshooting 16 Exploded Drawing 06879 Sub 1010FS 17 Parts List...

Страница 4: ...SAFETY INSTRUCTIONS IMPORTANT Please read the following instructions carefully failure to do so could lead to serious personal injury and or damage to the water pump 21 Ref No Description SIP Code Ref...

Страница 5: ...check for any damage and determine that it will operate correctly and perform its intended func tion Check for alignment of moving parts free running of moving parts breakage of parts and any other co...

Страница 6: ...wanted hazards Never use flammable or corrosive liquids to clean the water pump Never use the water pump to pump anything other than water it should not be used to pump flammable corrosive or other po...

Страница 7: ...lica tions Draining of cisterns rainwater reservoirs wells ponds swimming pools storm drains flooded cellars boats and yachts They are only for use with water and not chemicals or other substances tha...

Страница 8: ...markings in your plug pro ceed as follows The wire which is coloured blue must be connected to the terminal marked with N or coloured black The wire which is coloured brown must be connect ed to the t...

Страница 9: ...butor as soon as possible Note Proof of purchase will be required before any warranty can be hon oured GUARANTEE ELECTRICAL CONNECTION cont Warning Never connect live or neutral wires to the earth ter...

Страница 10: ...urrent circuit breaker tripped 3 Power supply problem 4 Float switch problem 5 Impeller jammed 1 Check and replace with correct rated fuse 2 Check and reset 3 Check with a qualified elec trician 4 Man...

Страница 11: ...ter to remove debris Re fit the base and o ring and secure with the retaining screws 1 2 3 1 2 3 06879 06881 06885 Screws Clean and store the pump in a dry and frost free place after each use the am b...

Страница 12: ...e water pump Push your hose onto the hose adaptor see page 12 Secure using a relevant pipe clip or similar pipe clip not supplied Lower the pump into the water use rope or similar around the handle to...