Advanced Settings
To change the thermostat's setting you need to:
3 sec.
3-year limited warranty
SINOPÉ TECHNOLOGIES INC. warrants the components of their
products against defects in material and workmanship for a 3 year
period from the date of purchase, under normal use and service,
when proof of purchase of such is provided to the manufacturer.
This warranty does not cover any transportation costs that may be
incurred by the consumer.
Nor does it cover a product subjected to misuse or accidental
damage.
The obligation of Sinopé Technologies Inc., under the terms of this
warranty, will be to supply a new unit and this releases the
manufacturer from paying the installation costs or other
secondary charges linked to replacing the unit or the components.
660-1120-0004-F
For more information, visit our website at:
www.sinopetech.com
OFF
(active for 6 sec if a button is pressed)
ON
(always active)
(Default: OFF)
1
Parameters & settings
Default
Display
Backlight
Temperature format
°C or °F
Temp
SHT
(short cycle for electric baseboard)
FAN
(long cycle for fan-forced heat)
Control Cycle
3
Cycle
Light
Press and hold the button for 3 seconds to exit the
menu and return to normal display.
Press the button to select the next parameter.
Press the button to change the setting.
Get the setpoint to its minimum and
hold the button for 3 seconds to
access the menu.
Order
Technical specifications
Operating voltage:
120/208/240 VAC, 60 Hz
Setpoint range:
5 ˚C to 30 ˚C (41 ˚F to 86 ˚F)
Display range:
0 ˚C to 70 ˚C (32 ˚F to 99 ˚F)
Resolution:
± 0.5 ˚C (± 1 ˚F)
Storage:
-20 ˚C to 50 ˚C (-4 ˚F to 122 ˚F)
TH1120-3000 thermostat
Maximum load:
12.5 A / 3000 W @ 240 VAC
Resistive load only
Minimum load:
0.5 A / 120 W @ 240 VAC
TH1120-4000 thermostat
Maximum load:
16.7 A / 4000 W @ 240 VAC
Resistive load only
Minimum load:
0.5 A / 120 W @ 240 VAC
Compatible
with an electric heating system such as:
Ÿ
Baseboard heater
Ÿ
Convector (short cycle)
Ÿ
Fan-forced convector (long cycle)