660-2131-0000-E
TECHNICAL SPECIFICATIONS:
MAXIMUM LOAD PER DIMMER FOR A SINGLE
OR A MULTI-GANG INSTALLATION:
Single installation
Multi-gang (2 units)
Multi-gang (3 units)
Protocol: Zigbee 3.0
Frequency:
2.4 GHz
Transmission power:
+20 dBm
Receiver sensitivity:
-108 dBm
Neviweb® is a registered trademark of Sinopé Technologies Inc. in Canada and the United States.
Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries.
App Store is a service mark of Apple Inc., registered in the U.S. and other countries. Google Play
and the Google Play logo are trademarks of Google Inc.
Incandescent
Lamp
600 W
500 W
400 W
600 W
500 W
400 W
150 W
150 W
150 W
Halogen
Lamp
Dimmable
LED / CFL
ADD YOUR DIMMER TO THE GT130 GATEWAY
AND NEVIWEB
Tap the then select "Add Device"
2
1
If you do not have an account yet,
download the Neviweb app for iOS or
Android to open an account and add
your device.
Follow the steps of the Installation Wizard
3
3-year limited warranty
SINOPE TECHNOLOGIES INC. warrants the components of their products against
defects in material and workmanship for a 3-year period from the date of purchase,
under normal use and service, when proof of purchase of such is provided to the
manufacturer. This warranty does not cover any transportation costs that may be
incurred by the consumer. Nor does it cover a product that has been improperly
installed, misused or accidentally damaged.
The obligation of SINOPÉ TECHNOLOGIES INC., under the terms of this warranty,
will be to supply a new unit and this releases the manufacturer from paying the
installation costs or other secondary charges linked to replacing the unit or the
components.
For more information, visit our Website:
Transmitter Module IC: 5123A-GM210P / FCC QOQGM210
This device complies with Industry Canada license exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) this device does not cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy, and if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
OFF and ON, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Operating voltage:
120 Vac, 60 Hz
Operation temp.:
0 °C to 40 °C (32 °F to 104 °F)
Storage:
-20 °C to 50 °C (-4 °F to 122 °F)
Standard UL:
Conforms to ANSI/UL Std. 1472
Standard CSA:
Certified to CAN/CSA Std. C22.2#184.1
PROVIDED CONNECTORS SPECIFICATIONS:
Stripping length: 16 mm
Wires: 22-10 AWG, Cu
Combinations: Max. 2 #12 & 2 #14, Min. 3 #20 Sol.
16 mm
DISCONNECT YOUR DIMMER FROM
THE GT130 GATEWAY OR A
COMPATIBLE ZIGBEE SYSTEM
CONNECT YOUR DIMMER TO THE GT130 GATEWAY OR A COMPATIBLE ZIGBEE SYSTEM
To disconnect your dimmer from the GT130
gateway or a compatible Zigbee system, press
the 2 buttons of the dimmer simultaneously for
10 seconds.
1
Connect all your dimmers the
same way, by going to the next
closest dimmer.
3
When all your devices are
connected, close the
connectivity session of
your GT130 gateway or
your compatible Zigbee
gateway.
4
Connect your dimmer to the gateway by pressing
simultaneously the two dimmer buttons for 1 second.
The indicator flashes blue = Connecting
The indicator turns green = Connected
If the connectivity fails, the indicator will
turn red. Refer to our Website to
troubleshoot the unit.
After a few seconds, the indicator
changes color depending on the dimmer status.
(Turned ON = blue, Turned OFF = amber)
2
Hub
2nd
1st
3rd
Initiate the connectivity session
by pressing the RF signal button
on the GT130 gateway. The
indicator light will start flashing.
Compatible Zigbee gateway:
refer to the installation guide
for the latter.
TROUBLESHOOTING
LED bulbs flicker at low intensity
The minimum dimming light intensity can be adjusted in the
Neviweb app to prevent the LED bulbs from flickering.
See the following link for more information:
https://support.sinopetech.com/en/1.2.3.2.1/