I.   Enter “SETUP” and then press                   until “DIRECT” 

 

appears in message window.

 

Press !ENTER) to enter direction setup;

 

X window, Y window and Z window will display “O” or  “I”  

 

against them.

2.  Select an axis by pressing the “X”, “Y” or “Z” button and then  

 

press enter. This will display  “O” or  “I” against the “X” 

 

 axis.

3.  Using the                    to change the display from “O” to  “I” to  

 

change the direction of the scale. Once the change has  

 

been made press  “enter” to confirm and save the change  

 

and exit the setup section.

CHANGING THE SCALE DIRECTION.

After the scales have been installed it may be necessary 

to change the direction of the scale so that it reads cor-

rectly. E.G. If you are using the scale on a lathe, then the 

scale that reads the diameter must get smaller as the 

tool gets closer to the centre.

This is all controlled by the display unit in the “SETUP” 

section. 

é

ê

or

If the linear scale is installed as the figure below (facing operators):

Direction “0” means the display value will increase when scale moves from right to left and 

decrease when scale moves from left to right.

é

ê

or

Page 6

Instruction Manual for XH-2 (D5200)

16/04/2019

Содержание XH-2

Страница 1: ...INSTALLATION MANUAL Page 1 Instruction Manual for XH 2 D5200 16 04 2019...

Страница 2: ...ce of the machine wherever possible In the case where there are no machined flat surfaces available optional backing plates are available and should be used Wherever possible the scale ends and the re...

Страница 3: ...and Tapping Holes 7 When drilling and tapping the holes be sure that the drill and tap are square to the cover Fig 6 All tapped screw holes must have at least 6 threads to allow the screw to be firmly...

Страница 4: ...parallelism of the two mounting surfaces must be less than 0 1mm b If the mounting surfaces are perpendicular to each other i e As per shown in figure C the squareness of these two mounting surfaces m...

Страница 5: ...d can be set with feeler gauge to allow the reader head to move unrestricted along the scale Fig 12 Scale Direction Before mounting the scales it is important that the scale reads in the correct direc...

Страница 6: ...and exit the setup section CHANGING THE SCALE DIRECTION After the scales have been installed it may be necessary to change the direction of the scale so that it reads cor rectly E G If you are using t...

Страница 7: ...r head and scale which allows for the correct clearance and holds the reader head parallel to the scale Fig 16 Mount the cover over the scale and drill and tap the holes to secure it to the table maki...

Страница 8: ...low for the travel of the slide Fig 21 FITTING THE Z AXIS SCALE Before mounting the scale ensure that it will read as you wind the table down increasing the distance from the table to the cutter The Z...

Страница 9: ...ls in line and square to the scale to avoid any damage to the scale Testing for parallel can be done by either a dial indicator or a precision level Fig 26 The cover must be fitted Fig 28 Fig 29 The l...

Страница 10: ...crews Fig 34 Fig 35 Fig 36 Fig 37 The DRO is mounted to the bracket using the two angle brackets and the mounting pin and secured with the bolt supplied Fig 37 FINDING A SUITABLE MOUNTING POINT Before...

Страница 11: ...11 DIMENSIONS Page 11 Instruction Manual for XH 2 D5200 16 04 2019...

Страница 12: ...12 Sino MK 500 Series Compact Scales L Effective measuring length of scale L L 102 L 112 56 73 6 3 5 18 43 5 25 0 5 43 20 20 14 4 DIMENSIONS Page 12 Instruction Manual for XH 2 D5200 16 04 2019...