37
Figure 25 The circular zone plate.
The zone plate is a two-dimensional linear frequency sweep with the
highest frequencies at the edges of the image. It can be used to measure
the horizontal and vertical frequency response of system. For example, in
figure 26, I show a horizontal line of video and you can clearly see that the
left and right edges of the waveform droop, showing some high frequency
attenuation.