pg. 12
Copyright © 2017- www.SingleTact.com
Reading outside of the valid range will fail.
I
2
C slave Read operations simply return the register data values up to the number of requested bytes
(32 max) in the data packet.
NOTE:
A sensor output reading below
0x0100
may indicate negative pressures, which occur when
the sensing area is under tension. This should be avoided since it can damage the internal structure
of the sensor.
NOTE:
Sensor over pressure should be limited to less than 3x FSR to avoid damaging the sensor.
Table 5 I
2
C Master Read from Slave Data Packet Format
BYTE
FROM SENSOR
0 - 31*
Register Data Read Location-Read L31*
* number of bytes read can be modified by a preceding read-request command.