8 HOW TO REMOVE AND INSERT
NEEDLES
• TO REMOVE NEEDLE (S)
* Be sure to disconnect the machine from the
electric outlet before removing needle(s).
* Turn the hand wheel toward you until the needle
is at its highest position.
* Loosen, but do not remove the needle set screw
with the small screwdriver.
—
left needle set screw (T)
—
right needle set screw (2)
* Remove the needle(s).
* TO INSERT NEEDLE (S)
* Hold the needle with the flat surface to the back.
* Insert the needle into the needle clamp as far as it
will go,
Note:
The left needle (3) will be slightly higher
than the right needle (4).
* Securely tighten the needle set screw.
Note:
This machine uses #2054 needles. Refer to
page 4 for additional needle information.
A
Flat surface to the rear