Specification 

Model n. 

STUFA-INFRAROSSI-PARETE-2000 

CH20A11CWR1 

STUFA-INFRAROSSI-TERRA-2000 

CH20A11CSR1 

Installation 

Wall mounted 

Standing 

Voltage 

230-240V~, 50Hz 

230-240V~, 50Hz 

Power(W) 

2000 

2000 

Installation 

Wall 

Standing 

Product size(mm) 

596*135*320 

Heater size: 596*135*320mm 

Base in dia. 500mm 

Height of assembled set:2100mm 

Insulation 

Class I                           

Class I                           

Water proof 

IP65 

IP65 

 

 

IMPORTANT INFORMATION   

Please read the operation manual carefully before installing and using the infrared heater.   

This user manual contains important information about your safety, as well as some recommendations on 

the correct use of the device and its maintenance.   

Keep  the  operating  manual  together  with  the  warranty  certificate,  the  sales  receipt  and,  if  possible,  the 

cardboard packaging and packing material.   

The infrared heater you have purchased may be somehow different from the one described in the manual, 

but this does not affect how it is used and how it works.   

Important precautions and instructions provided in this owner's guide do not include all possible ways and 

situations you may encounter. You must understand that common sense, prudence and care are factors that 

cannot be "built into" any product. 

 

1.

 

SAFETY INSTRUCTIONS 

 

Read the instructions before installation and use. 

Certain precautions must be observed when using the 

infrared heater. Improper operation without observing the precautions may cause damage to the health of 

the user and other persons as well as damage to their property.   

 

Use only the voltage indicated on the heater nameplate. 

 

Connect the unit only to a properly installed power outlet with ground contact.   

 

The heater must be connected to the power supply with a 2-pole circuit breaker. 

 

It is strongly recommended to use a 30mA differential switch. 

 

The unit must be handled with care and avoid vibration or shock. 

 

Do not use the unit in areas where gasoline, paint or other flammable liquids are used or stored. 

 

Do not place any clothing, towels or the like on top of the heater to dry. Risk of overheating and fire 

 

Do not use the apparatus in areas where there is a particular risk of explosion. 

 

Caution: To avoid burns, do not touch the surface of the unit with your hands or other body parts.   

 

Do not leave the heater unattended during use. 

 

Do not use this heater on a wet surface, or where it may fall or be pushed into water. 

 

Do not touch a device that has fallen into water. Turn off the power and unplug immediately. 

 

If the power cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified 

persons to avoid a hazard. 

 

If the heater is defective, it must be checked and repaired by the manufacturer, its service agent or similarly 

Содержание CH20A11CSR1

Страница 1: ... Version 2021 9 13 Infrared heater STUFA INFRAROSSI PARETE 2000 CH20A11CWR1 STUFA INFRAROSSI TERRA 2000 CH20A11CSR1 The photo is only indicative the real device may appear slightly different in color ...

Страница 2: ...before installation and use Certain precautions must be observed when using the infrared heater Improper operation without observing the precautions may cause damage to the health of the user and other persons as well as damage to their property Use only the voltage indicated on the heater nameplate Connect the unit only to a properly installed power outlet with ground contact The heater must be c...

Страница 3: ...to come into contact with heated surfaces during operation Do not run the cable under carpets rugs runners etc Place the cord away from areas where it may trip Children under 3 years of age should be kept away unless they are continuously supervised Children between 3 and 8 years of age should turn the appliance on or off only if it has been placed or installed in the intended normal operating pos...

Страница 4: ...istances required for installation Wall mounted STUFA INFRAROSSI PARETE 2000 CH20A11CWR1 Caution The unit should only be operated in a horizontal position with a maximum slope of 5 Never install the unit on a flammable surface plastic nylon cardboard etc Install the device at a minimum distance of 2 2 m above ground 0 5 m from the walls 0 2 m from ceiling 1 5 m from flammable like curtains 1 m fro...

Страница 5: ... Do not use the heater near curtains and other combustible materials Do not heat the wall directly The minimum distance between the wall and the heater must be more than 0 5 m 1 8 m above ground 0 5 m from the walls 0 2 m from ceiling 1 5 m from fuels like tents 1 m from people or animals AVOID USE IN THE BATHROOM ...

Страница 6: ...mounting bracket 2 2 1 Install wall mounting bracket with 4 screws ST5 x 35mm not supplied and 4 plastic plugs not supplied 2 2 2 Insert the groove of the adjustable bracket on the stop of the fixing bracket 2 2 3 Lock the fixing bracket and the adjustable bracket with 2 pieces M6x16 Philips Bolt and wing nut ...

Страница 7: ...erial and design of the ceiling or wall structural elements the heater must be fixed with the correct fasteners The weight of each heater is 4 1 kg The installation structure and hardware must be able to support 5 times the weight of each heater It is the installer s responsibility to choose the correct wall or ceiling mounting Fixing bracket ...

Страница 8: ...sion 2 3 Pedestal Installation CH20A11CSR1 The CH20A11CSR1 contains the following components Heater x 1 Set of bases and poles Series Photo part Part Name Quantity A Hexagonal wrench 1 B Hexagon head screw M6 x 40 3 C Base 1 D Bottom pole 1 ...

Страница 9: ...E Central pole 1 F Top pole 1 G Bracket 1 H Secure the Hardwire M6 x 16 Philips bolt spring washer wing nut 4 ...

Страница 10: ...INFRAROSSI PARETE 2000 STUFA INFRAROSSI TERRA 2000 CH20A11CWR1 CH20A11CSR1 The distance between the heater and the remote control should be less than 3 meters and the remote control should be pointed directly at the receiver ...

Страница 11: ... up Press off the heater is set to standby mode Point the remote at the receiver and press the 1 button the 1 hour delay timer will activate With 1 hour delay the heater stops heating and goes into standby mode Consequently the heater can be set with a timer of 2 hours 4 hours 6 hours maximum 13 hours delay 4 CLEANING Disconnect the unit from the power supply After the unit has cooled down the hou...

Страница 12: ...contact the dealer where you purchased the product They may take this product for environmentally safe recycling Batteries must be disposed of in accordance with current regulations Production FOSHAN CITY SHUNDE DISTRICT WARMTEK ELECTRICAL CO LTD Address N 302 NINETEEN BUILDING PHASE 3 RONGLI TIANFULAI INDUSTRIAL PARK RONGGUI SHUNDE FOSHAN GUANGDONG CHINA Made in China Imported in Italy by M P C s...