17
Pollution
Level
Accumula-
tive operat-
ing time
(hour)
Pollution
Level
Accumula-
tive operat-
ing time
(hour)
Pollution
Level
Accumula-
tive operat-
ing time
(hour)
18
9500
28
4600
38
900
19
10000
29
5000
39
1000
(4) When absent function is set, the setting temperature will display 8°C, the setting
fan notch displays auto and cannot be adjusted.
(5) When I-Demand function is set, the temperature area will display “SE”, the set-
ting fan notch displays auto and cannot be adjusted.
3.9
Setting of Other Functions
3.9.1
Setting of Energy-saving Function
Under power-off status, press “TIMER” and “▲” buttons simultaneously for 5
seconds to enter into energy-saving setting, then “SAVE” character or icon and
cooling mode icon are displayed, the “SAVE” character or icon flashes, the temper-
ature area displays the upper limit and lower limit temperature, press “▲” or “▼”
button can set the limit temperature(setting range is 16–30). Press “MODE” button
can switch cooling or heating mode. For cooling only unit, it can only set the lower
limit temperature of cooling under energy-saving mode. During the setting, press
“SWING/ENTER” button at any time can save the setting temperature and energy-
saving status of different modes, and then start up the energy-saving function.
After the energy-saving function is activated, under power-off status, press “TIM-
ER” and “▲” buttons simultaneously for 5 seconds again, the function is canceled.
3.9.2
Setting of Low-temperature Dry Function
Under dry mode, when the setting temperature is 16°C, press “▼” button for
twice, the setting temperature becomes 12°C, then the unit enters into low-
temperature dry function.