11 - MAINTENANCE
If the replace or control of the electric heater
x
Remove power supply
x
Remove frontal cover (A)
x
Unscrew the screws and remove the cover cap (B)
x
Turn off the water inlet valve (C)
x
Open hot water tap for decrease the pressure of the
storage tank.
x
Open tap (D)
x
Empty the storage up to point (E)
x
Disconnect the cable from the electric heater
x
Remove and replace the electric heater (If faulty)
x
Install the electrical resistance and make sure effective
sealed.
x
Check that there are no water losses from the fitting
x
Restore the electric connections
x
Put the cover cap (B) and fix
x
Put de frontal cover (A)
x
Open the water inlet tap (C) untill water flows out from
outlet tap, then turn of water outlet tap.
x
Power on then restart the unit.
11.14 REPLACE OR CONTROL THE ELECTRIC
HEATER
A
D
C
B
E
Electric heater
11.15 CONDENSATE DISCHARGE
Dust and deposits could cause obstructions .
In addition in the pan can proliferate microorganisms and
moulds.
It is very important to provide a periodic cleaning with
appropriate detergents and in case a disinfection with
sanitizing products.
After cleaning pour water into the pan to ensure a regular flow.