15
Installation & Owner‘s Manual
In vacation period, the setting target water
temperature is 15
ć
as default and will show
the remanent vacation days. On the last day of
vacation, unit will automatically start disinfect
function, and automatically reset the target
temperature to the last one before vacation.
If unit has already been in vacation or OFF, press
will lead to show invalid icon on the
display.
Enter vacation setting. Icon
will
flash. Icon will be lightened.
will show last setting vacation days.
Press button for 3sec to enter
disinfect clock setting. Then icon will
flash, and icon will be lightened
and the hour value of clock will flash slowly.
VACATION
CANCEL
CLOCK
TIMER
DISINFECT
ON/OFF
3.1
3.2
3.2
Icon
Description
DISINFECT
No
Icon will flash.
Set the hour value of clock.
Set the minute value of clock.
Set vacation days. The days range is 1~99
days(default as 14 days).
Confirm vacation setting and quit out. The
unit will immediately go into vacation.
Confirm the disinfect clock setting and
quit out.
Confirm manually activate disinfection
function , then the unit will heat up water to
65
ć
at least for disinfection.
CONFIRM/UNLOCK
If screen and buttons are unlocked, press it to
upload setting parameters after setting any
parameter:
● If press it within 10sec, setting parameters will be
uploaded to unit;
● If press it beyond 10sec, please resetting all
parameters.
If screen and buttons are locked, press it for 3s to
unlock them.
Manually turn on disinfect function
Disinfect Clock Setting
Confirm the hour setting. Then the minute
value of clock will flash slowly.
Unit will automatically start disinfect function at the
above-set clock every 7 days.
If user don't set disinfect clock, unit will automatically
start disinfect function at 23:00 every 7 days.
If unit is OFF or under disinfect mode, press
will lead to show on the display.
VACATION
Vacation Setting
5.3 Combination button
5.4 Auto-restart
5.5 Button Auto Lock
Icon
Description
No
No.
Icon
Description
Clear error
code
Query
+
+
Press the two buttons at
the same time to clear all
stored error & protect
codes, and the buzzer
will buzz one time.
Press the two buttons at
the same time for 1sec to
go into querying. On
querying user can check
unit setting & running
parameters by pressing
circularly.
Press button for
1s or no button operation
for 30s, then quit
querying.
If electricity power failed, unit can memorize all setting parameters,
unit will be back to the previous setting when power recover.
When there is no operation of button for 1 minute, button will be
locked except Unlock button , Press ) for 3s, unlock
buttons.
5.6 Screen Auto Lock
If there is no operation of button for 30s, screen will be locked
(extinguished) except for error code and alarm light. Press any button
will unlock the screen(lighten)
ķ
Ĺ
ĺ
Ļ
ļ
Ľ
ľ
Ŀ
ĸ
ON/OFF
FAN
Содержание SWH-15/190T
Страница 1: ...OWNER S MANUAL SWH 15 190T SANITARY WATER HEATER H E A T P U M P S...
Страница 2: ......