Sinclair FC-H07AIF Скачать руководство пользователя страница 1

USER'S MANUAL

FC-H07AIF, FC-H09AIF, FC-H12AIF

FREE COMBI SERIES

Содержание FC-H07AIF

Страница 1: ...USER S MANUAL FC H07AIF FC H09AIF FC H12AIF FREE COMBI SERIES ...

Страница 2: ... T T ...

Страница 3: ...r installation 3 4 5 6 11 12 13 14 18 17 19 22 23 The instructions before use Models and specifications Names and functions of each part wireless remote control opreation procedure Operation and maintenance Installation and aftersales service Installation and Maintenance of Healthy Filter CONTENTS Thank you for choosing SINCLAIR air conditioner please read this owner s manual carefully before oper...

Страница 4: ...vices Can t be connected to the water pipe gas pipe sewage drain or the places where are not reliable earthed Cut off the power Whenhavingaburningsm ell or smoke please turn off the power supply and contact with the service center If abnormity still exists the air conditioner could be dam aged or may cause electric shock or fire Don t attempt to repair the air conditioner by your self The improper...

Страница 5: ...y away from the outdoor un it for more than 1 meter It is likely to ignite and ex plore GAS Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the air con ditioning capacity or cause a malfunction Airflow from the air condi tioner can cause incomp lete combustion to the sp ace heater and may cause intoxication of carbon mo noxide ...

Страница 6: ...240V 50Hz Working temperature range Maximum cooling Minimum cooling Maximum heating Minimum heating Indoor side DB WB 32 23 21 15 27 20 Model Cooling capacity W Heating capacity W Rated power supply Noise dB A Climate Type Waterproof level Isolation Weight kg Indoor unit boundary dimensions WxHxD mm FC H12AIF 3500 3800 40 FC H07AIF 37 2100 2600 ...

Страница 7: ...4 Names and functions of each part Air in Displayer Front panel Guide louver Air out Wireless remote Wrapping tape control ...

Страница 8: ...o switch appliance on or off 10 button off automatically is used to switch the air conditioner When the appliance is on this button 9 TIMER OFF button buttons 7 8 ROOM TEMPERATURE SETTING Used to set the room temperature When the appliance is off this button 6 TIMER ON button is used to switch the air conditioner on automatically Used to start or stop the movement of 5 SWING button the vertical lo...

Страница 9: ...es last around one year The batteries in the remote control must be disposed of appropriately according to the legislation in force in the country concerned TIPS ON STORING AND USING THE REMOTE CONTROL The remote c ontrol can be stored in a special support mounted on the wall The remote control holder is an op tional accessory HOW TO USE THE REMOTE CONTROL To switch the air conditioner on aim the ...

Страница 10: ...t the FAN button is pressed the AUTO LOW MEDIUM HIGH 3 Setting the temperature Press once to increase the set Press once to decrease the set temperature by 1 C Range of temperature settings available temperature by 1 C HEATING 16 C 30 C COOLING 16 C 30 C DEHUMIDIFICATION 16 C 30 C FAN ONLY HEATING AUTO COOLING DRY FAN ONLY 16 C 30 C speed is speed is changed in the following sequence ...

Страница 11: ...20 C 25 C higher than 25 C Lower than 20 C PREVIOUE MODE OR FAN COOLING HEATING prior to being switched off Press the button When the unit is switched on it will start operating in the mode selected 4 Starting the appliance displaying AUTO in automatically based on the actual room temperature The operating mode and the temperature setting depend on the room temperature In AUTO mode the pre set tem...

Страница 12: ...tart operating in the mode selected AUTOMATIC STOP When the appliance is on press theT OFF button to set the time you want the air conditioner to switch off pressing theT ON button again increases the time by 30 minutes until a maximum of 24 hours from E g If the setting is performed at 8 30 p m andtheTIMERissetto3 5h theappliance 2 5 30 minutes until a maximum of 24 hours liance will start at 6 3...

Страница 13: ...rature the compressor the outdoor unit will stop If the room temperature is more than 0 5 C above the set temperature the appliance automatically starts in dehumidification mode When the unit is heating if SLEEP operation C C C SLEEP MODE When the unit is cooling or drying if SLEEP operation is set SET TEMP would increase 1 in 1 hour and 2 in 2 hours is set SET TEMP would decrease 1 in 1 hour and ...

Страница 14: ...ricity leakage pro tection switch of enough power capacity and air switch with enough space 25A earth wire cannot be connected to gas pipe water pipe or wires of the lightning rod and telephone Clean the air filter seriously and carefully maintaining it Adjust to the suitable temperature Too cool will do harm to the health Avoid directly lighting and cool air leaking Please take out the batteries ...

Страница 15: ...nction The supply cords of this air conditioner is adopting Y type connection If the supply cord is damaged it must be replaced by man ufacturer or its service agent or a similarly qualified person in order to avoid a hazard Air conditioner could be operated with the voltage fluctuation 230 10 Otherwise compressor would vibrate terribly to damage refrigeration system Don t use the air conditioner ...

Страница 16: ...nel according to direction of direction of arrow 1 then take out the filter or water when the filter is dirty oil it can be 1 Uplift the panel a little bit from the direc tion of arrowhead 1 then insert the filter 2 Uplift the panel according to the direction 3 Insert the clamp A B C back to three the rotating shaft and cover the panel Installation of filter washed by warm water below 45 dissolvin...

Страница 17: ...by yourself it can cause an electric shock or fire Please check the following items before asking for repair it can save your time and money waiting Check before use 1 Be sure that nothing obstructs the air outlet and intake vents properly connected or not 3 Check that whether the batteries of Maintenance after use 1 Clean filters and other parts 2 Turn main power off 3 Clear dust from the outdoor...

Страница 18: ... the cold wind and it looks like the fog Creaking noise can be heard when start or stop the unit This is caused by the deformation of plastic due to the change of tempera ture Air conditioner does not operate at all Trip off Has the power been shut down Is the wiring loose Is the leakage protection switch in operation Is voltage higher or lower Is TIMER ON in operation Cooling Heating efficiency i...

Страница 19: ...abnormal heat in power supply cord and power plug Phenomenon Trouble Shooting Wireless remote control is not available Remote control can t be used occasionally when the air conditioner is disturbed or changing its functions frequently At that time pull out the power plug and insert it again to recover the operation Is the remote control out of effective disance to the indoor unit Are there any ob...

Страница 20: ...ore installation to avoid the malfunction due to unprofessional installation The installation must be done by trained and qualified service personnel with reliability according to this manual Installation dimension diagram NOTE The indoor unit installation of dual split type unit is taking one of the indoor units for example the installation of another indoor unit is the same as that one The dimen...

Страница 21: ...or inflamm able gas Install in a location where is strong enough to withstand the full weight and vibration of the unit Ensure the indoor unit installation accord with the installation dimension Be sure to leave enough space to allow access for routine maintenance The indoor unit should be installed at 2 3m or higher above the floor Select a place about 1m or more away from the TV set or any other...

Страница 22: ...nect the connection pipes with the indoor unit Be careful in bending the connection pipes or you If the tightening torque is too great in tightening Electric wiring 1 Open the panel upwardly 2 Disassembly the fixing bolts of connection cover shown in the Fig at right side 3 power connecting wire cross through down to up from the bottom of case Fig 1 Bent Wrenched cover of connection connection pow...

Страница 23: ...t as shown in fig 4 c 2 Cut off tailings 1 and 2 when connection pipe and power cord are routed wire Wire Line bank gloove Power connect 1 Cut off tailings 1 when only power cord is routed blue black yellow green Methods are recommended piping ways 2 After wrapped pipe and wire pull them though the pipe hole as shown in fig 5 3 Hang the mounting slot behind indoor unit on the pothook of the rear p...

Страница 24: ...21 Right pipe Rear right pipe a Left pipe Rear left pipe b c Tailings 1 Tailings 2 Fig 4 Fig 5 Wrapping strap Coonection pipe Power connect wire Signal control wire Drainage hose Fig 6 ...

Страница 25: ... unit is running press ON OFF to stop unit from running Check after installation Items to be checked Is the installation firm enough Possible malfunction Unit may drop shake or emit noise Is leakage test done It may cause insufficient of cooling heating capacity Is heat insulation sufficient Condensation or water drop may occur Is drainage smooth Condensation or water drop may occur product namepl...

Страница 26: ...healthy filter commonly has its usage lifetime for one year under normal condition As for silver ion filter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and reinstall it after cleaning Cleaning and Maintenance Service Life downwards to remove it See Fig a techin or mite killing filt...

Отзывы: