)XQFWLRQDQG&RQWURO
1RWHV:DWHUEXFNHWPXVWEHFRUUHFWO\LQVWDOOHGIRUWKHGHKXPLGL¿HUWRRSHUDWH
'RQRWUHPRYHWKHEXFNHWZKLOHXQLWLVLQRSHUDWLRQ
:KHQWKHXQLWLVFRQQHFWHGWRSRZHU32:(5LQGLFDWRURQFRQWUROSDQHOZLOOEHRQDQGWKHXQLWZLOOJLYHRXWDVRXQG
(DFKWLPHSUHVVLQJWKHHIIHFWLYHEXWWRQRQWKHFRQWUROSDQHOZLOOJLYHRXWDEHHSVRXQG
&RQWURO3DQHO,QVWUXFWLRQ
If unit is turned on and running in timer mode for 2hr or 4hr,can turn off the unit. When unit stand by and running in
timer mode for 2hr or 4hr can ture on the unit.
4
3
2
1
5
6
4 hour or 2 hour delay
on/off indicator lights
High and Low fan
indicator lights
Bucket full light indicates bucket
needs to be emptied or it is not in
the proper place
Continuous operation on
indicator light
Power On indicator light
Clean the Filter indicator light
ON/OFF Pad
Press to turn the dehumidifier on and off.
FILTER Pad
After 250 hours of operation, the Clean the Filter indicator light will glow to remind you to clean the filter. Remove the
filter and clean it. Press to turn off the Clean the Filter light. See the Care and Cleaning section.
Humidity Set Control Pads
The humidity level can be set within a range of 80% RH (Relative Humidity) to 35% RH (Relative Humidity) in 5%
reduce or at CO for continuous operation.NOTE: If CO (Continuous) is selected, the dehumidifier will operate
continuously at its maximum dehumidification settings if attached to a hose to drain or until the bucket is full.For
drier air, press the - pad and set to a lower percent value (%).For damper air, press the + pad and set to a higher
percent value (%). When you first use the dehumidifier, set the humidity control to 45% or 50%. Allow at least 24
hours for the dehumidifier to achieve the humidity level. If you still have damper air than desired, set the humidity
level to a lower setting or select Continuous for maximum dehumidification.
This unit has 3-min lag due to the device
for protecting circuit .In order to prolong
the compressor's working life, the compressor
will not start until the unit has
run for 3 minutes.
Display
Shows the set % humidity level while setting, then shows the actual (+/– 5% accuracy) room % humidity level.
Controls the fan speed. Press to select High or Low fan speed. Set the fan control to High for maximum moisture
removal. When the humidity has been reduced and quiet operation is preferred, set the fan control to Low.
TIMER Pad
FAN SPEED
1
2
3
4
5
6
Содержание CFO-16E
Страница 1: ...SERVICE MANUAL CFO 16E MOBILE DEHUMIDIFIER ...
Страница 2: ......
Страница 3: ...CFO 16E 6XPPDU 3DUW ĉ 7HFKQLFDO QIRUPDWLRQ ...
Страница 5: ... 2XWOLQH LPHQVLRQ LDJUDP 8QLW PP 496 225 353 ...
Страница 29: ... 6 WHPSHUDWXUH DQG KXPLGLW FKDUDFWHULVWLF ć ć 5HODWLYH KXPLGLW 7HPSHUDWXUH ć 5 ć ć ć ć ć ć ć ć ć ć 8QLW ȍ ...
Страница 30: ... 6 WHPSHUDWXUH DQG KXPLGLW FKDUDFWHULVWLF ć ć 5HODWLYH KXPLGLW 7HPSHUDWXUH ć 5 ć ć ć ć ć ć ć ć ć ć 8QLW ȍ ...
Страница 31: ... ...
Страница 32: ... 6 KDUDFWHULVWLF RI WHPSHUDWXUH DQG KXPLGLW ć ć 5HODWLYH KXPLGLW 7HPSHUDWXUH ć 5 ć ć ć ć ć ć ć ć ć ć ć 8QLW ȍ ...
Страница 33: ... ...
Страница 34: ...PARTS GUIDE CFO 16E DEHUMIDIFIER ...
Страница 35: ...Exploded view of model CFO 16E ...