indoor electrical wire
display board
1.
2.
As shown in Figure 7, the indoor unit has one
set of control signal wires, with 1 wiring
terminals in total.
Figure 7
As shown in Figure 6, the outdoor unit has two
sets of outgoing wires, which are power cord
(high current) and the control signal wires
respectively. The former one should be directly
connected to the power supply terminal while
the latter one should be connected to the
control signal wire of the indoor unit.
ROUTING 220-240V AC WIRING
STEP 5-ELECTRICAL WIRING
- 1
6
-
WARNING
Make sure that all power supply to the unit is disconnected before performing any work on the
unit to avoid the possibility of shock or injury and/or damage to the equipment. When the interior
ceiling assembly frame is properly secured to the roof top air conditioner, the following electrical
connections must be performed.
3.
Connect the docking terminals of indoor
unit and outdoor unit, see Figure 8.
outdoor connect wire
outdoor
electrical
wire
Figure 6
Figure 8