Installation Services
—
Install Outdoor Unit
-20-
Fig 12
Fig 13
Outdoor Drainage
Faucet
Vacuum-pumping and Leakage Inspection
1. Remove the nut cover at the shutoff valve.
2. Align with the center of the fitting pipe and manually
tighten the conical nut sufficiently.
3. Use spanner to tighten the conical nut.
4. Remove the liquid valve cap, the gas valve cap and
the nut of refrigerant charging mouth.
5. Use inner hexagon spanner to twist off the liquid valve
body and at the same time use screwdriver to open
the valve core of the liquid valve. Now gas shall flow
out.
6. After gas continues flowing out for about 15 second
and refrigerant gas begins to flow out, close the valve
core and tighten the nut of refrigerant charge mouth.
7. Completely open the valve body of the liquid valve
and the gas valve.
(
See Fig 12
)
8. Turn and tighten the valve cap, then use soap water
or a leak detector to check if there is gas leakage at
the outdoor and indoor units and the pipeline
connections.
9. If conditions permit, use a vacuum pump to exhaust
air in the unit from the valve core.
(
See Fig 13
)
Draining of Condensate Water of Outdoor Unit (Cooling
Only Unit Does Has Such Valve)
When the air-conditioning unit is in the heating mode, the
condensate water generated at the outdoor unit and the water
generated by defrosting shall be drained through the drainage
pipe to proper place.
Installation methods :
As shown in Figure, insert the drainage
joint of the outdoor unit into the
Φ
25 hole on the base plate.
Connect the drainage pipe to the drainage mouth so as to drain
the condensate water and water generated by defrosting to
proper place.
Chassis of
Outdoor Unit
Gas Pipe
Liquid Pipe
Liquid Valve
Inner Hexagon Spanner
Gas Valve
Refrigerant Charge Mouth
Screwdriver
-76cmHg
manifold valve
Multi-
meter
Manometer
Hi hand
le
Lo hand
le
Charging hose
Charging hose
Low
-
pressure valve
Vacuum Pump
Install the power line
1. Remove the front side plate.
2. Pull all wires through the rubber bush.
3. Remove the wire clamp and connect the end of
the power connection cord with screws to the
4. Make sure that the wiring has been
5. Tighten the wire with clamp and clasp.
wiring terminal board according to the "WIRING
DIAGRAM" of outdoor unit.
connected firmly.
Handle
Cable Clamp
Power
Connection Cable
Connecting Block for Indoor Unit
Coo/Heat
Model Diagram
Power
Connection
Cable
Connecting Block for Outdoor Unit