Operating Procedures / Photos
Respectively unsolder the weld spots of main
capillary and auxiliary capillary to take off the
capillary.
Capillary
Unscrew the two bolts fixing gas valve and liquid
valve.Unsolder weld spots between gas valve and
and air-return pipe to remove the gas valve.
Unscrew the two bolts fixing liquid valve. Unsolder
weld spots between liquid valve and capillary to
remove the liquid valve.
(Note:During unsoldering ,wrap the valves with
wet cloth to avoid damage for high temperature.)
Bolts
Unscrew the three foot-nuts at the foot of the
compressor. Unsolder the suction and the dis-
charge pipes of the compressor,and then care-
fully remove the pipes to take out the compressor.
Liquid Valve
Gas Valve
Weld spots
Nuts with washers