10.Overload and high discharge temperature malfunction
Main detection points:
ƽ
If the electronic expansion valve is connected well? Is the electronic expansion valve damaged?
ƽ
If the refrigerant is leaked?
ƽ
The compressor overload protection terminal is not connected well with the mainboard?
ƽ
If the overload protector is damaged?
ƽ
Heat exchange of unit is not good? (heat exchanger is dirty and unit radiating environment is bad)
ƽ
Too much load of the system causes high temperature of compressor after working for a long time?
ƽ
Malfunction of discharge temperature sensor?