![Sinclair ASH-09AIE2 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/sinclair/ash-09aie2/ash-09aie2_service-manual_1280135011.webp)
7
Technical Information
Service Manual
4. Refrigerant System Diagram
Indoor unit
Outdoor unit
COOLING
HEATING
Accumlator
4-Way valve
Discharge
Suction
Heat
exchanger
(evaporator)
Heat
exchanger
(condenser)
Valve
Valve
Liquid pipe
side
Gas pipe
side
Compressor
Strainer
Strainer
Capillary
Indoor unit
Outdoor unit
COOLING
HEATING
4-Way valve
Discharge
Suction
Heat
exchanger
(evaporator)
Heat
exchanger
(condenser)
Valve
Valve
Liquid pipe
side
Gas pipe
side
Strainer Electron
expansion
valve
Strainer
Capillary
Accumlator
Compressor
Connection pipe specification:
Liquid pipe:1/4" (6mm)
Gas pipe:3/8" (9.52mm)