11
circumstances. Circumstances which work against
efficiency of the units include e.g. bad insulation of the
building, large window areas, south facing, attic
apartment, many additional heat sources, such as e.g.
number of persons, EDP, light, kitchen units, washing
units etc.
unit does not
cool correctly
You achieve the most effective and economical cooling
comfort if you already cool the room to be cooled when
the room temperature is not yet heated up. Air
conditioners operate more effectively if the temperature
is to be maintained. To drastically cool the air and
inventory in a fully heated room requires much more time
and energy.
E1 Room
temperature
outside the function
range:
Room temperature
inside the function
range:
Observe all data in these operating instructions
concerning function range.
New measurement of start temperature. Please switch
the unit off and start it again after approx. 30 minutes. If
the error occurs continuously, the unit requires specialist
inspection.
E2
Temperature of the
cooling agent lines too
high or too low
Temporary error on measuring output temperature.
Please switch the unit off and start it again after approx.
30 minutes. If the error occurs continuously, the unit
requires specialist inspection.
E3 Incorrect
signal
This error message in the cooling function refers to too
high ambient temperatures, and in the heating function
to too low ambient temperatures. Please observe the
instructions relating to ideal operation of the unit. This
may also be a temporary error measurement between
the start and output temperature. Please switch the unit
off and start it again after approx. 30 minutes. If the error
occurs continuously, the unit requires specialist
inspection.
E4
Water tank full
If the water tank is full, the warning sign "E4" appears in
the display. To restart operation of the unit, please
remove the plug of the condensation water outlet to
allow water to leak out. Please use an appropriate
collection tank. When the water has been completely
removed, please start the unit again. The unit can now
be used as usual.
DF
Defrosting mode
This procedure is completely normal and protects the
system from icing and failure. The unit starts
automatically after approx. 15 minutes again (depending
on the function setting). This procedure repeats itself
regularly.
Switching the
units from °F to °C
and viceversa.
Solution
Please switch off the unit to STAND-BY mode by
pressing the button POWER on the unit (the unit is
plugged in). Hold for 5-10 seconds button FUNC on the
unit and after a beep sound switch on the unit by button
POWER.
SPARE PARTS AND ACCESSORIES SUPPLY (FAST CONVENIENT SUPPLY)
You can obtain spare parts and accessories for your unit from your local dealer.
www.sinclair-eu.com
NOTE CONCERNING PROTECTION OF ENVIRONMENT
This product must not be disposed of via normal household waste after its service life, but must be taken
to a collection station for the recycling of electrical and electronic devices. The symbol on the product, the
operating instructions or the packaging indicate such disposal procedures. The materials are recyclable in
accordance with their respective symbols. By means of re-use, material recycling or any other form of
recycling old appliances you are making an important contribution to the protection of our environment.
Please ask your local council where your nearest disposal station is located.