background image

USER'S MANUAL

 AMC-12AN

MOBILE SERIES

Содержание AMC-12AN

Страница 1: ...USER S MANUAL AMC 12AN MOBILE SERIES ...

Страница 2: ...L AND SPECIFICATIONS STRUCTURE OPERATING METHODS NAMES AND FUNCTIONS OF THE REMOTE CONTROLLER CARE AND MAINTENANCE TROUBLE SHOOTING USER NOTICES AFTER SERVICE OPERATION OF THE REMOTE CONTROLLER 11 12 13 15 ACCESSORIES AND INSTALLATION OF HEAT EXHAUST HOSE 21 CIRCUIT DIAGRAM ...

Страница 3: ...eference and the technical parameters are subject to change without notice WORKING PRINCIPLE With the help of upper motor the airflow of indoor passes through the evaporator becomes the cooling wind but with the help of lower motor the airflow of indoor passes through the condenser becomes the heating wind It was designed two duct systems in its structure The heating wind is discharged by the rear...

Страница 4: ...FICATION 4 Noise is tested 1m in front of front air outlet vent under cool air state it is sound press grade 5 Please refer performance parameter on nameplate as standard The design are subject to be changed without notice 3 Max cooling input power is tested under cooling mode when indoor temp dry bulb 35 and wet bulb 24 Note 1 Cooling capacity is tested when indoor temp dry bulb 35 and wet bulb 2...

Страница 5: ... 3 STRUCTURE Front Rear Air outlet Controller panel Handle Remote box Upper air inlet grille Air exhaust outlet Lower air inlet grille ...

Страница 6: ...ad wires and any continued use lead wire is no less than 2 5mm2 The air conditioner must be safety earthed Earth wire must be connected to the special device of the building In order to provide the good earthing for the air conditioner The appliance must be positioned so that the plug is accessible If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a simi...

Страница 7: ...e fuse the capability of the fuse must be appropriate In order to avoid the power cord damaged and electrical leakage do not fix the power supply on the knife edge or the sharp object The wiring must be operated by the professional and according to the national regulations 5 ...

Страница 8: ...n 1 ON OFF key Press once to start and press once more to stop the unit 2 MODE key Press this button to change the operation mode in order of COOL DRY FAN HEAT 3 key In COOL and HEAT mode press once the SET TEMP will decrease 1 once the SET TEMP key will increase 1 1 The SET TEMP can be selected from 16 61 30 86 Press 1 F F F F HEAT mode COOL ...

Страница 9: ...eed itisnotadjustable COOL mode CAUTION DRY mode When in cooling or dehumidifying mode the dew water will drain into the tank When the tank gets full the indicator will flash and the buzzer will sound eight times LED window shows error code H8 at the same time the unit stop running WATER Cut off the power supply move the appliance to a suitable place to pull out the plug and pour out the water in ...

Страница 10: ...p will be decreased by 1 The temp will be changed quickly the button continuously and setting temp range is by pressing Swing up and down button below Press this button the running mode will change as Mode button MODE could turn on or turn off the Up and down swing function When unit is turned off synchronously press and Up and down swing buttons it could be switched between the simpleness swing m...

Страница 11: ... to change timing value quickly then remote controller will send out the signal immediately and hour on off will stop flickering If the time of that no press timer button under flickering status is above 5s the timer setting will quit If the timer has been set press this button once again to quit it press this key once again to fix the time There is no this function for this unit If press this key...

Страница 12: ...ight in the displayer will be on When the LIGHT is off the icon will be disappeared and all the indicators light in the displayer will be off Light button LIGHT Press this button enter into SLEEP state when repressed it will quit The sleep function and FAN mode will be canceled with the stop of the unit There is no SLEEP function under AUTO is the icon for sleep function SLEEP Sleep button At COOL...

Страница 13: ...unction on or off 5 Press TURBO button to set this function on or off Guide for operation optional operation Introduction for special function This function indicates that moisture on evaporator of indoor unit will be blowed after the unit About X FAN function is stopped to avoid mould 1 Having set X FAN function on After turning off the unit by pressing ON OFF button indoor fan will continue runn...

Страница 14: ...n remote controller will display H1 If switch to heat mode the position will display H1 which flickers for 5s in which case press button H1 will disappear and setting temp be displayed After remote controller is powered on the new defrost function will be defaulted to be closed About lock About AUTO RUN About new function of defrosting The appliance of the defrosting function is unavailable will b...

Страница 15: ... recommended to use it with shortest length When installing exhaust pipe should be as flat as possible Don t prolong the pipe or connect it with other exhaust pipe or Correct installation is as shown in figure When installing it on wall height of hall should be about 130cm from floor it would cause abnormal operation ...

Страница 16: ...STALLATION OF HEAT EXHAUST HOSE following dimension bent too much it would easily cause malfunction 14 If the pipe are to be bent please install it by considering Wrong installation is shown in following figure If the pipe is ...

Страница 17: ... 15 ACCESSORIES AND INSTALLATION OF HEAT EXHAUST HOSE PARTS INCLUDED Window Exhaust Adapter Rear plastic pipe end Flexible Exhaust Hose Front plastic pipe end ...

Страница 18: ...nt of the unit has lots of dust the cleaning of air filter should be more frequently Disassembly and Cleaning Pull out the tab of the filter take out the air filter Wash the filter solely to spray like the spray in bath and to shake the filter Or to immerse filter into the gentle soap water then dry it in a shade WARNING The mobile air conditioner WARNING Clean the air filter Recommended once ever...

Страница 19: ...se a cloth slightly moistened with water below 40 104 or the soap water or the water with cleanser after wresting wipe the dirt Do not use the gasoline diesel oil or the congeneric substance to clean the unit Before cleaning please pull out the power plug GAS F ...

Страница 20: ... plug tightly 2 Ask for the electrician to replace 3 Ask for the electrician to replace the fuse 1 This is the normal phenomenon 2 Unit is running in defrosting operation it will come back to run in original operation after defrosting 1 Unit is running in defrosting operation it will come back to run in original operation after defrosting To cut off power supply after 10 minutes turn on the unit i...

Страница 21: ...r a long time it can cause the health problems The unit should be placed about 1m or more away from the TV or it will be effected by the electromagnetic wave The air inlet outlet can t be blocked by the obstruction or it will cause the malfunction Do not insert hands or stick into the air inlet or outlet especially pay more attention to young children or it can cause the accident easily This appli...

Страница 22: ...overturn If the abnormal phenomenon occurred please pull out the power plug at once and inform the dealer to check and maintain Do not use the insecticide or other sprays it can cause deformation or crack DISPOSAL Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary ...

Страница 23: ...CIRCUIT DIAGRAM The circuit diagrams of all above are for reference they are subject to change without notice AMC 12AN ...

Отзывы: