background image

- 3 -

• Make sure main body is never submerged in water.
• Clean the inner parts with a soft cloth. Do not use any solvents or aggressive cleaning
agents to clean the appliance.
• Only use the brush to clean to transducer .This should be done once a week. Only use
the soft-bristle portion of the brush.
• Change the water in the tank at least once a week if water is standing for more than
a week.

Trouble shooting
Problem: 
Indicator not illuminated, no air, no fog
Possible cause: The power plug is not properly plugged
Possible cause: The power switch is not turned on
Possible cause: The water level in the water bath is too high
What to do: Plug the power properly
What to do: Turn on the power switch
What to do: Pour out some water in the water bath screw down the water tank cover

Problem: Indicator illuminated with air, no fog
Possible cause: There is no water in the water tank
Possible cause: The automatic constant humidity knob is not turned on.
Possible cause: The water level float cap is not held down.
What to do: Top up the water tank
What to do: Turn on the automatic constant humidity knob clockwise
What to do: Hold down the water level float cap
Problem: Spray with odor
Possible cause: New unit
Possible cause: The water in the tank is not clean
What to do:  Open the water tank
What to do:  Place at a shade for 12 hours
What to do:  Clean or replace the water tank
Problem: Small fog output
Possible cause:There is scale formation on the transducer
Possible cause: The water is dirty or has been stored too long
What to do:  Clean the transducer
What to do:  Replace with clean water

INFORMATION ABOUT USAGE FAULTS
Only use the specified voltage for the appliance. Check with your local voltage to see if
they match. To avoid any risk hazards, a damaged power cable must be changed by the
manufacturer, service organization or a likewise qualified technician. Do not attempt to
disassemble the device yourself in case of a failure, contact our call centre.