Limit Switch Adjustment
Hz T5 Operators
_
+
+
_
+
_
_
+
+
_
_
+
+
_
_
+
UP LIMIT ADJUSTMENT SCREW
DOWN LIMIT ADJUSTMENT SCREW
DOWN LIMIT ADJUSTMENT SCREW
UP LIMIT ADJUSTMENT SCREW
MATERIAL ROLLS DOWN ON SAME SIDE AS LIMITS
MATERIAL ROLLS DOWN ON OPPOSITE SIDE FROM LIMITS
1) Identify which limit adjustment screw controls the up limit and which controls the down limit (see above diagrams). It is important
to note that the arrows by the limit adjustment screw refer to the tube's rotation. Thus if the material comes off the tube on the back
side and the limit adjustment screws face the front (as per diagram 2), the limit adjustment screw facing up controls the down limit
and vice versa.
2) Turning an adjustment screw clockwise will increase the maximum travel in the direction that it controls, and turning it
counterclockwise will decrease the maximum travel.
3) To set a limit, run the motor in the selected direction.
4) If the motor stops on its own before reaching the desired stop, turn the appropriate limit screw positive (clockwise). Every 2 to 3
turns of the limit adjustment screw will allow the motor to travel about 1 inch further. After every few turns of the limit adjustment
screw, use the control switch to move the motor to the new limit position. (If the motor does not stop on its own before reaching the
desired limit, go to step 6)
5) When you are approximately at the desired limit position, use the control switch to run the motor away from the limit 2 to 3 feet,
and then back. This will allow you to see precisely where the limit is set. Make small adjustments and repeat.
6) If the motor does not stop on its own at least 6 inches before the desired limit position, stop the motor with the control switch.
Then turn the limit adjustment screw in the negative (counterclockwise) direction. Confirm that the motor is stopped at the limit and
set the limit as per steps 4 and 5. If the motor is not stopped at the limit, continue turning the limit adjustment screw
counterclockwise (up to 120 turns may be required )
NOTE: The motor has a built in thermal cutoff. If after several minutes of use the motor will not run in either direction, allow the
motor to cool for approximately 20 minutes.