background image

Limit Switch Adjustment 
Hz T5 Operators

_

+

+

_

+

_

_

+

+

_

_

+

+

_

_

+

UP LIMIT ADJUSTMENT SCREW

DOWN LIMIT ADJUSTMENT SCREW

DOWN LIMIT ADJUSTMENT SCREW

UP LIMIT ADJUSTMENT SCREW

MATERIAL ROLLS DOWN ON SAME SIDE AS LIMITS

MATERIAL ROLLS DOWN ON OPPOSITE SIDE FROM LIMITS

1) Identify which limit adjustment screw controls the up limit and which controls the down limit (see above diagrams). It is important 
to note that the arrows by the limit adjustment screw refer to the tube's rotation. Thus if the material comes off the tube on the back 
side and the limit adjustment screws face the front (as per diagram 2), the limit adjustment screw facing up controls the down limit 
and  vice versa.

2) Turning an adjustment screw clockwise will increase the maximum travel in the direction that it controls, and turning it  
counterclockwise will decrease the maximum travel.

3) To set a limit, run the motor in the selected direction.

4) If the motor stops on its own before reaching the desired stop, turn the appropriate limit screw positive (clockwise). Every 2 to 3 
turns of the limit adjustment screw will allow the motor to travel about 1 inch further. After every few turns of the limit adjustment 
screw, use the control switch to move the motor to the new limit position. (If the motor does not stop on its own before reaching the 
desired limit, go to step 6)

5) When you are approximately at the desired limit position, use the control switch to run the motor away from the limit 2 to 3 feet, 
and then back. This will allow you to see precisely where the limit is set. Make small adjustments and repeat.

6) If the motor does not stop on its own at least  6 inches before the desired limit position, stop the motor with the control switch. 
Then turn the limit adjustment screw in the negative (counterclockwise) direction. Confirm that the motor is stopped at the limit and 
set the limit as per steps 4 and 5. If the motor is not stopped at the limit, continue turning the limit adjustment screw 
counterclockwise (up to 120 turns may be required )

NOTE: The motor has a built in thermal cutoff. If after several minutes of use the motor will not run in either direction, allow the 
motor to cool for approximately 20 minutes.

 

counterclockwise

1

2

R

7

Содержание TSA Hz 2

Страница 1: ...R Hz 2 Radio Control Systems Programming Manual www simu com ...

Страница 2: ...use one motor for two or more shutters add 20 for the first additional shutter to derive the total weight Add an additional 10 for every shutter after that Examples 2 shutters one motor 20 to the total weight 3 shutters one motor 20 10 to the total weight If the shutter is over 9 feet in height add 10 to the total weight for every three feet beyond Example 11 feet in height total weight an additio...

Страница 3: ... 380 173 380 Model Type Model Type 505 510 515 525 530 535 550 505 510 515 525 530 535 550 37 lbs 30 lbs 62 lbs 49 lbs 92 lbs 74 lbs 154 lbs 123 lbs 185 lbs 148 lbs 216 lbs 172 lbs 308 lbs 246 lbs 50mm 2 0 inch TUBE DIAMETER 60mm 2 5 inch TUBE DIAMETER kg lb 9 20 18 40 27 60 36 80 45 100 55 120 64 140 73 160 82 180 91 200 100 220 109 240 118 260 127 280 136 300 145 320 155 340 164 360 173 380 Mode...

Страница 4: ...e listed charts reflects the recommended 30 security factor that is used for most applications Shutters more than 9 feet high add 10 to the effective load for every additional 3 feet Double span shutters add 20 to the effective load to be lifted kg lb 9 20 18 40 27 60 36 80 45 100 55 120 64 140 73 160 82 180 91 200 100 220 109 240 118 260 127 280 136 300 145 320 155 340 164 360 173 380 Model Type ...

Страница 5: ...hich roller tube diameter D is being used in your installation 3 Locate the number of arms B and the length of your installation C 4 Read the correct motor from the chart at the intersection of your selections NOTE Because this chart must take into consideration lateral arms being manufactured by many different companies it is only approximate The relationship between the number of arms and the le...

Страница 6: ...w positive clockwise Every 2 to 3 turns of the limit adjustment screw will allow the motor to travel about 1 inch further After every few turns of the limit adjustment screw use the control switch to move the motor to the new limit position If the motor does not stop on its own before reaching the desired limit go to step 6 5 When you are approximately at the desired limit position use the control...

Страница 7: ...it adjustment screw use the control switch to move the motor to the new limit position If the motor does not stop on its own before reaching the desired limit go to step 6 5 When you are approximately at the desired limit position use the control switch to run the motor away from the limit 2 to 3 feet and then back This will allow you to see precisely where the limit is set Make small adjustments ...

Страница 8: ...trical Code and local codes The Hz operator can be wired to power in parallel unlike normal AC tubular operators It is recommended that provisions be made to cut power individually when wiring Hz operators This can be in the form of an inline off on switch a disconnect plug or access to the operator cable for use of a installers power cable with off on switch The ability to cut the power to each m...

Страница 9: ...ou can put to one switch The only limitation is the range a transmitter can reach This is approximately 70 feet through walls and up to 100 feet in open air Single motor to multiple wireless switches There is a limit of 12 transmitters of any type to one motor Hz 2 Type 5 DMI Operator Basic Rules and Scenarios R 10 ...

Страница 10: ...ouping to a master control can be accomplished without the use of external controls The ability to parallel wire the Hertz operators makes it easy to wire Simply supply power to the electric operator and program the wireless transmitter to the motor or motors of choice and you are done For more information about other options available please consult a SIMU representative for more details Hz 2 Typ...

Страница 11: ...the up button now makes the shutter go up IMPORTANT The motor is supplied in Factory Mode Set direction of rotation 1 before pressing the program button 2 Programming the Transmitter Hold the transmitter within 10 feet of the motor head example 4 Press and hold the Program Button about 1 second until the motor jogs forward and then back Transmitter range will now be approximately 100 ft You can no...

Страница 12: ...he up button now makes the shutter go up 2 Programming the Transmitter You can now proceed to the up and down limit settings Hold the transmitter within 10 feet of the motor head example 4 Press and hold the Program Button about 1 second until the motor jogs forward and back Transmitter range will now be approximately 100 ft 3 Disconnect the Power to Motor After the above steps are completed disco...

Страница 13: ... limit settings Hz Type 5 DMI Operator Scenarios 1 Setting Direction of Rotation The motor will be in Factory Mode right out of the box when power is connected To prepare the motor for programming press the transmitter up and down buttons simultaneously until motor jogs forward and back example 1 Hold the transmitter within 10 feet of the motor and press the up button example 2 If the motor rotate...

Страница 14: ...e receiver on metallic surfaces as this will reduce the range If mounted outside make sure to use the watertight strain reliefs and mount the box so the strain relief fittings face downward to avoid rain seepage 2 If using a hardwired low voltage switch locate it no more that 100 feet from the receiver The UL Listed Hz Receiver allows control of any standard non Hz T5 or T6 motor from any of the H...

Страница 15: ... Use only dry contacts as switch inputs to the Hz Dry Contact Interface To activate an up stop or down command a momentary contact closure is required between common and the desired input up stop or down Program Button C FC be La l BACK OF TRANSMITTER SIDE OF TRANSMITTER Program Button Program Button c Hz Dry Conta t Interface EF 6301072 R PROGRAMMING Use a standard Hz transmitter to wake up the m...

Страница 16: ...0v 60hz This interface control is compatible most A V system hook ups Recessed Designer Multi Channel 5 independent channels that can be programmed to operate one or more motors Available in white and ivory Slim Multi Channel Hand Held 5 independent channels that can be programmed to operate one or more motors Available in white Single Channel Surface Wall Mount Available in white Program Button P...

Страница 17: ...inc Plated 510000 Shade Bracket 50mm spacing 4mm tapped holes Zinc Plated 520038 Shade Bracket Motor mount 10mm square pin For Type 5 operators Zinc Plated 520073 Awning Bracket 48mm spacing 6mm tapped holes Zinc Plated Awning Bracket 48mm spacing 1 4 US threaded tapped holes Zinc Plated 520040 520188 Awning Bracket 50mm spacing 6mm tapped holes Zinc Plated 520041 R 22 ...

Страница 18: ...e Bracket 30mm spacing 1 4 US Threaded holes Attaches to wall bracket 520210 Gold Zinc Plated 252527 Shutter Bracket Maxi side frame bracket 100x100mm Requires side frame center pin to be removed Gold Zinc Plated 520187 Shutter Bracket Mini side frame bracket 80x80mm No center pin removal required Gold Zinc Plated Bracket Fitting Set Type 5 bracket fitting set 520049 850365 R 23 ...

Страница 19: ...ting mode if left for 2 minutes C Returning to Original Factory Mode Deleting All Transmitters Note When the motor is in Factory Mode is the only time the direction of rotation can be changed It is also recommended that the limits be set while the motor is in factory mode as it takes continuous pressure on the transmitter button to move the motor To return the motor to Factory Mode make a double p...

Страница 20: ...4 2 Press the up button and confirm the motor runs up 4 3 If the motor runs down instead of up press and hold the stop button until the motor gives an up dn bounce 1 Identify which limit adjustment screw controls the up limit and which controls the down limit see diagrams on right It is important to note that the arrows by the limit adjustment screw refer to the tube s rotation Thus if the materia...

Страница 21: ... a double power cut in the following sequence 1 Power off for at least 2 seconds 2 Power on for 5 to 15 seconds 3 Power off for at least 2 seconds 4 Power on The motor will try and run up for 3 seconds but will not run past its limit The motor is now in a Temporary Mode last for 2 minutes NOTE THIS IS NOT FACTORY MODE Press and hold the Program Button of any un memorized transmitter for more than ...

Страница 22: ...turns of the limit adjustment screw will allow the motor to travel about 1 inch further After every few turns of the limit adjustment screw use the control switch to move the motor to the new limit position If the motor does not stop on its own before reaching the desired limit go to step 6 5 When you are approximately at the desired limit position use the control switch to run the motor away from...

Страница 23: ...w treatment below When the UP direction is activated the window covering will raise The 3 Activate the UP direction using the low voltage switch If the motorized treatment will move for the duration the switch is activated When the switch is window treatment does not raise or retract reverse the black and red wires moved to the CENTER position the motors will stop on both motors 4 When the treatme...

Страница 24: ...nt screw use the control switch to move the motor to the new limit position If the motor does not stop on its own before reaching the desired limit go to step 6 5 When you are approximately at the desired limit position use the control switch to run the motor away from the limit 2 to 3 feet and then back This will allow you to see precisely where the limit is set Make small adjustments and repeat ...

Страница 25: ......

Страница 26: ......

Отзывы: