2/2
a
>>
>>
+
b
0,5s
3s
6s max.
>>
3s
>>
3s
>>
3s
2.5. Adjustment of down end limit:
- With the T5 ESP / T 6ESP motor, there is no manual adjustment for the upper
end limit.
a.
Position the motor on the desired down end limit using the
and
b.
To memorize the down end limit, press
twice:
1st press for half a second without the motor rotating.
2nd press over 3 seconds, so the motor rotates briefly one way, then the other*.
2.3. Opening the end limit setting mode:
- Press simultaneously on
and
for 3 seconds. The motor will run briefly in one direction and then in the
other*. Go to step 2.4.
2.6. Validation of end limits:
- Press the
and
keys simultaneously for at least 3 seconds. The motor briefly rotates one direction and
then in the other*.
2.4. Initializing obstacle detection:
- Press on
for 3 seconds. The motor will run briefly in one direction and then in the other*. Go to step 2.5.
- Mandatory use of a reversing switch that stops the
and
keys being activated
simultaneously.
- Possibility of wiring 3 T5 motors maximum in parallel on one switch.
- Be careful of the direction of rotation (§2.2)
- The cable may only be connected to the motor by qualified personnel.
- The connector is to be assembled without damaging the contacts.
- The continuity of the earth connection must be ensured.
- The length of the cable between the electrical switch and the motor must not
exceed 50 m.
- Please do contact SIMU when using KNX / EIB electronic switching control devices.
Final wiring
3
Blue
Brown
Black
Green/yellow
PE
L
N
Permitted power on a specialised line
Fuse 10 A
Circuit breaker 16 A
766 W
1226 W
- With the T5 ESP / T6 ESP motor, there is no manual adjustment for the upper end limit.
a.
Position the motor on the down end limit set in §2.5 using the key
.
b.
Press the ▼ key 6 times, each time for 6 seconds. After the 2nd, 3rd, 4th, 5th, and 6th press the motor rotates briefly one way, then
the other*.
c.
Position the motor on the new desired lower position using the
and
keys.
d.
To confirm the new end limit position, press
twice, once for half a second without the motor rotating and the second time for at least
3 seconds, so the motor rotates briefly one way, then the other*.
Re-adjustment of down end limit
4
>>
>7s
>>
2s
7s
- Connect the motor to the settings switch (§2.1)
- Press the
and
keys simultaneously, for at least 7 seconds. The motor rotates
one way, then the other, then a few seconds later rotates in both directions.
After this operation, the motor returns to its factory settings, repeat the
operations from chapter 2.
Cancelling of end limit adjustments
5
- The settings are now complete. There is no delay time any more in motor operation. You can now connect the
motor to the final reversing switch (§3).
* Press the buttons until the motor turns into the two directions.
c
a
0,5s
>3s
d
+
6s max.
b
>>
>>
>>
>>
>>