OCTOEASY
MANDATORY
STEEL
1
3
2
2
1
3
1
4
2
5.3 Nm max
These instructions apply to all T5 AUTOSHORT BHz drive, the different versions of which are available in the current catalogue.
Field of application
: T5 AUTOSHORT BHz drive are designed to drive all types of roller shutters equipped with stop
blocks and rigid links. The installer, who must be a motorisation and home automation professional, must ensure that the
drive product is installed in accordance with the standards in force in the country in which it is installed such as EN 13659
relating to roller shutters.
Liability: Before installing and using the drive, please read operating and installation guide carefully.
Please
read these instructions carefully before installing and using the drive. In addition to following the instructions given in this
guide, the instructions detailed in the attached
Safety instructions
document must also be observed. The drive must be
installed by a motorisation and home automation professional, according to instructions from Simu and the regulations
applicable in the country in which it is commissioned. It is prohibited to use the drive outside the field of application
described above. Such use, and any failure to comply with the instructions given in this guide and in the attached
Safety instructions
document, absolves SIMU of any liability and invalidates the warranty. The installer must inform its
customers of the operating and maintenance conditions for the drive and must provide them with the instructions for use
and maintenance, and the attached
Safety instructions
document, after installing the drive. Any After-Sales Service
operation on the drive must be performed by a motorisation and home automation professional. If in doubt when installing
the drive, or to obtain additional information, contact a SIMU adviser or go to the website
www.simu.com.
Instructions which must be followed by the drive and home automation professional installing the
drive:
- Methods of wiring are given by national standards or IEC60364 standard.
- Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
- The cable for the motor can be removed. If it is damaged, replace by the same. The cable may only be
connected to the motor by qualified personnel. The connector is to be assembled without damaging the
contacts. The continuity of the earth connection must be ensured.
Recommendations:
Keep a minimum distance of 20 cm between two T5 AUTOSHORT BHz motors. Keep
a minimum distance of 30 cm between T5 AUTOSHORT BHz motors and BHz transmitters. A radio appliance
using the same frequency (868-870 MHz) may deteriorate our product’s performance. To receive information
regarding the compatibility of the motor and the roller shutter or/and accessories, contact the roller shutter
manufacturer or SIMU.
Drilling of the tube:
Mounting:
Installation
1
351
4 x Ø5 / 90°
47
min.
364
387
4
22,8
55
48
IP44
120
45
24
T5 AUTOSHORT BHz 06/17
1/4
EN
SIMU S.A.S. au capital de 5 000 000 € - Z.I. Les Giranaux - BP71 - 70103 ARC-LÈS-GRAY CEDEX - FRANCE - RCS VESOUL B 425 650 090 - SIRET 425 650 090 00011 - n° T.V.A CEE FR 87 425 650 090
EN
T5 AUTOSHORT BHz
(230V~50Hz)
5140363A
Original
instructions
-20°C / +60°C
i