TROUBLESHOOTING

It is best to begin troubleshooting at the Access Point, because the rest 
of the system depends on it for network synchronization and configu-
ration. If the Access Point has problems, the operation of the entire 
network will be affected.

All radios in the network must meet these basic requirements:

• Adequate and stable primary power

• An efficient and properly aligned antenna system

• Secure connections (RF, data & power)

• Proper programming of the unit’s operating parameters, espe-

cially Device Mode selection (Access Point/Remote), Network 
Name, and IP Address

• The correct interface between the radio and the connected data 

equipment (proper cable wiring, data format and timing)

Table 5

 provides suggestions for resolving common system difficul-

ties using the front panel LEDs as a guide. 

Table 6 on Page 17

 pro-

vides guidance using the Menu System as a tool. 

If problems persist, review the SIMREX Web site’s technical support 
area for general troubleshooting help, service information, and recent 
software/firmware updates at 

www.simrex.com. 

Additional help is 

available from the SIMREX Technical Services Department. 

See 

“TECHNICAL ASSISTANCE” on Page 20

 for contact information.

Table 5. Troubleshooting Using LEDs

Symptom

Problem/Recommended Checks

PWR LED 
does not 
light.

a. Voltage too low—Check for proper supply voltage at 

the power connector (10.5–30 Vdc).

b. Indefinite Problem—Cycle the power and wait 

(

30 seconds) for the unit to reboot. Then, recheck for 

normal operation.

PWR LED is 
blinking. 

a. Blinking indicates the presence of an alarm condition. 

b. View Current Alarm List and Error Log and correct the 

problem if possible.

c. Blinking continues until the fault is corrected, for 

example, a valid IP address is entered, etc.

Содержание DataMover ESS Series

Страница 1: ...Installation Start Up Wireless IP Ethernet Transceiver ESS II Firmware Release 1 ESS Firmware Release 6 SIMREX MAN ESS INS Rev E MAY 2006 SIMREX CORPORATION DataMover ESS Series...

Страница 2: ...Refer to the Installation Reference Chart at the middle of this manual for essential installation and configuration details...

Страница 3: ...8 Step 4 Review the Transceiver s Configuration 8 Step 5 Connect the Data Equipment 10 Step 6 Check for Normal Operation 11 Resetting to Factory Defaults 12 Performance Optimization 12 INSTALLATION R...

Страница 4: ...ational Fire Pro tection Association NFPA publication NFPA 70 otherwise known as the National Electrical Code The transceiver has been recognized for use in these hazardous locations by two inde pende...

Страница 5: ...tions outlined in this manual Failure to comply with these instructions may also void the user s authority to operate this device Environmental Information The manufacture of this equipment has requir...

Страница 6: ...as Access Point unless they are first upgraded to Dual Gateway type This is accom plished with an Authorization Key purchased from the factory Each one of these individual software keys is associated...

Страница 7: ...ow An accompa nying concern is the cyber security of the communication infrastruc ture and the security of the data itself The transceiver is capable of dealing with many common security issues Table...

Страница 8: ...STEPS A typical product shipment consists of a transceiver a power con nector and this start up guide Below are the basic steps for installing a transceiver Should further information be needed see T...

Страница 9: ...e Fasteners anchors or screws are not normally supplied Four threaded holes are located on the bottom of the radio that are suitable for connecting mounting hardware Use 6 32 x 1 4 inch 6 mm screws to...

Страница 10: ...the left If the transceiver is to be powered at voltages of 28 Vdc or higher please review the User s Guide for important recommendations Invisibleplaceholder Figure 2 Power Connector Polarity Left Ri...

Страница 11: ...s or 1 Mbps ESS rates are 256 kbps or 512 kbps Password Used for remote access and Menu System features NOTE The default password is admin For web access a username is also required The default userna...

Страница 12: ...N port 10BaseT or one of the serial ports depending on the capability of your transceiver See Table 1 on Page 4 Use a straight through Ethernet cable to connect the LAN port to a hub and a crossover c...

Страница 13: ...System PING utility At Remote Units a Look for the LINK LED to turn on and remain on This indi cates the unit has successfully associated with the network s Access Point The association process may t...

Страница 14: ...lt admin you must enter a special code authorization key provided by the factory in place of the user name at the time of login Contact the factory for more information Performance Optimization After...

Страница 15: ...operates only in the CHANNELS mode with select able hopping from 1 to 75 channels Usage key for Channel Configuration Menu n no Radio channel is not used y yes Radio channel is used NA not available R...

Страница 16: ...ssociated with an Access Point unit by observing the LINK LED It should be on or blinking 2 View and record the Wireless Packets Dropped and Received Error rates This information will be used later Ma...

Страница 17: ...ter which it will return the transceiver to normal operation The Test Mode can also be terminated manually via the menu 3 Set the transmitter RF output power to 30 dBm Main Menu Maintenance Tools Menu...

Страница 18: ...g common system difficul ties using the front panel LEDs as a guide Table 6 on Page 17 pro vides guidance using the Menu System as a tool If problems persist review the SIMREX Web site s technical sup...

Страница 19: ...oth ends b Verify that the appropriate type of Ethernet cable is used straight through or crossover as required Table 6 Troubleshooting with the Menu System Symptom Problem Recommended System Checks R...

Страница 20: ...h local PING attempt to PING an IP unit attached to another radio d If successful with the LAN PINGs try connecting to a known unit in the WAN Wireless Retries too high Possible Radio Frequency Interf...

Страница 21: ...hardware 1 5 x 6 x 4 H x W x D 3 8 x 15 2 x 10 2 cm Weight 0 9 kg 2 lb Case Cast Aluminum RADIO CHARACTERISTICS GENERAL Frequency Range 902 928 MHz Industrial Scientific Medical ISM Band Mode Freq Hop...

Страница 22: ...SERVICE If return of the equipment is necessary please contact the SIMREX Technical Support Team You will be issued a Return Materials Authorization RMA number The RMA number will help expedite the re...

Страница 23: ...ns should be addressed to When repairs have been completed the equipment will be returned to you by the same shipping method used to send it to the factory Please specify if you wish to make different...

Страница 24: ...Installation Guide...

Страница 25: ...SIMREX Corporation 5490 Broadway St Lancaster NY 14086 PH 716 206 0174 FX 716 204 0476 Web www simrex com...

Отзывы: