Numerical presentation

On the PI display, the distance between 

the trawl doors is displayed in the numeric 

display. If the distance is increasing or 

decreasing, this is shown with two arrows 

and the variation in meters per second. 

When the readings are stable, the digits 

are shown in black colour. When the 

values are predicted, the digits are grey, 

and if the contact is lost, the characters 

***

 are shown in grey.  If the transvere 

communication link fails, this is indicated 

with the characters 

±±±

 .

Mounting

The Spread and Remote sensors 

must be mounted in special 

adapters on each trawl door. 

These adapters must be installed 

aforehand. Detailed information 

on how to install the adapters are 

provided with the installation kit.

Installation principle

The PI Spread sensor is mounted 

on the port door, while the PI 

Remote sensor is mounted on 

the starboard door. It is essential 

that there is a clear line of sight 

between the two transverse 

communication “eyes” (one on 

each sensor), and between the top 

of the PI Spread sensor and the 

hydrophone on the vessel.

System confi guration

Sensor configuration

: The sensor 

must be configured with a unique 

sensor number. Select channel number 

and update rate according to the 

sensor’s configuration. Write down the 

configuration for future reference.

Status & Receiver

: The Interference 

filter must be switched on. Set it to 

level 

9

 if you have noise problems from other 

hydroacoustic sources. Note that with 

the filter on, it will influence the signal 

spectrum shown in the 

Status display

.

Sensor filter

: Switch this filter to 

Light

Set it to 

Heavy

 only if you experience 

excessive noise. Position 

Off

 will provide 

Off

Off

raw data and fastest possible response.

(CD11009E)

A

D

D

E

G

B

C

F

(A) = Sensor set up as sensor no.3. The 

distance is measured in meters.

(B) = Current distance between the trawl 

doors.

(C) = The distance is increasing by 18 

meters per minute.

(D) = Arrows pointing “out” means 

that the distance is increasing. Arrows 

pointing “in” means that it is decreasing.

(E) = Graphic alarm

(F) = Indicator, lit for every sensor 

interrogation.

(G) = Interference symbol.

A

R

S

D

C

F

E

B

(CD11204E)

Top view:

(A) = Starboard door

(B) = Port door

(C) = Communication link to 

vessel’s hydrophone

(D) = Angle of attack

(E) = Direction of tow

(F) = Transverse communication 

link

(R) = PI Remote sensor in its 

adapter

(S) = PI Spread sensor in its 

adapter

Sacrifi cial water switch 

sensor

If the water switch on your 

sensor is a sacrificial brass screw, 

this screw must be checked every 

month. Whenever required due to 

wear and tear, the screw must be 

replaced. Refer to the operational 

procedures in the operator manual.