Simrad HS50 Heading Sensor
26
20221081 / F
Differential corrections
The signal cable with the differential corrections is connected to
the terminal block P205 on the Processing unit for RS-422 input
signal, and P206 for RS-232 input signal.
In the
Diff. corrections
submenu the correct baud rate and
format for the signal must be set. If
RTCM
format is selected,
the correct
RTCM
Options
must be selected to enable
differential corrections to be used in the position solution.
If data from more than one reference station are available on the
link, HS50 automatically uses the nearest reference station to
obtain the best solution. The default
RTCM Option
is
MSB 1st
and
6 of 8
.