Simrad GC80/85 Double System Controller
988-12721-001
63
SWITCH
DEFAULT
FUNCTION
DESCRIPTION
S2-1
OFF
Data output for record
(Not used)
SW2-1 OFF
No output
SW2-2 OFF
SW2-1 OFF
Output for old monitor
SW2-2 ON
S2-2
OFF
SW2-1 ON
Output for new monitor
SW2-2 OFF
SW2-1 ON
No output
SW2-2 ON
S2-3
OFF
Operating panel type
OFF = GPANEL (NOT FOR BAMS)
ON = GPANEL-A (FOR BAMS)
S2-4
OFF
Pendulum ferry
Not used
S2-5
OFF
Serial signal transmit
frequency IEC61162-1
ed.4
SW2-5 OFF
= 1 sec (1 Hz)
SW2-6 OFF
SW2-5 OFF
= 100 msec (10 Hz)
Note: If selecting 38400 baud
rate for the serial out the output
frequency will be:
50 Hz for HDT/THS and
50 Hz for ROT.
SW2-6 ON
S2-6
ON
SW2-5 ON
= 200 msec (5 Hz)
SW2-6 OFF
SW2-5 ON
= Invalid
SW2-6 ON
S2-7
OFF
Not used
S2-8
OFF
System select
information contact
OFF = No
ON = Yes
S3-1
OFF
Timer startup
OFF = No
ON = Yes
S3-2
OFF
Talker ID of “ROT”
sentence
OFF = “HE”
ON = “TI”
S3-3
ON
Rate of turn scale
SW3-3 OFF
Max 30.0 °/min.
SW3-4 OFF
SW3-3 OFF
Max 300.0 °/min.
SW3-4 ON
S3-4
OFF
SW3-3 ON
Max 120.0 °/min.
SW3-4 OFF
SW3-3 ON
Invalid
SW3-4 ON
Содержание GC80 EXPANDED
Страница 1: ...ENGLISH GC80 85 Double System Controller User Manual www navico commercial com...
Страница 2: ......
Страница 3: ...Simrad GC80 85 Double System Controller 988 12721 001 3 Document history Rev 001 First review...
Страница 31: ...Simrad GC80 85 Double System Controller 988 12721 001 31...
Страница 42: ...Simrad GC80 85 Double System Controller 42 988 12721 001...
Страница 43: ...Simrad GC80 85 Double System Controller 988 12721 001 43...
Страница 44: ...Simrad GC80 85 Double System Controller 44 988 12721 001...
Страница 45: ...Simrad GC80 85 Double System Controller 988 12721 001 45...
Страница 82: ......
Страница 83: ...988 12721 001...