Precaution:
Do not open the equipment, only authorized Simrad technicians
are qualified to do so. If the glass in the screen breaks, be carefull not to cut
yourself on the sharp edges of the glass pieces. There is high voltage present
inside the scanner which may also be present even after power is turned off.
)
The lifetime of the internal battery is minimum 5 years.
If not exchanged
before it goes flat, all data in the unit’s memory will be lost.
We strongly
recommend that you frequently store your data on a Simrad DataCard. For
exchange of battery, call your local Simrad workshop.
Power source, fuse and power cable:
Check that the DC power supplied to
the unit is within the range of 10 to 32 volts. Note that the appropriate fuse
must be employed (see fuse ratings in the Specifications). Ensure that the
power cord is firmly attached.
Grounding:
To reduce electrical interference and risk of electrical shock,
properly ground the NavStation to the ship’s ground using the ground screw
at the rear of the unit. Good grounding should also be exercised for connected
equipment.
Cleaning:
Do not use any kind of strong solvents e.g. spirit, alcohol, gasoline
or oils.
Software:
The software version of the main unit (see start-up display) should
always be informed in a service situation, or when ordering a Dual Station.
Содержание CX34 NavStation
Страница 1: ...INSTALLATION MANUAL SIMRAD CX34 44 54 NavStation 183 3450 102 06134 20 English...
Страница 4: ......
Страница 6: ...Table of contents Installation...
Страница 8: ...Installation 1 2 CX34 44 54 NavStation Other important settings...
Страница 19: ...CX34 44 54 NavStation Installation 1 13...
Страница 21: ...CX34 44 54 NavStation Installation 1 15...
Страница 53: ...CX34 44 54 series Installation 1 47 Connector for the Open Scanners RB716A RB717A and RB718A...
Страница 62: ...Installation 1 56 CX34 44 54 series...