background image

7

+

A

Circuit Breaker/Isolator

70A-0050711-12v
50A-0050710-24v

12v/24v

BATTERY

Single Direction Solenoid

0052505-12v
0052506-24v

B

Inline Fuse
12v-5 AMP, 24v-3.15 AMP

Deck Foot Switch

0052514

QU900/D
QU900/U

D

C

High Load Foot Switch

0052516

LEWP49C

LEWP49CW

+

C1250 CAPSTAN

Total Length Required =   A   +   B   +   C   +   D

Only one type of switch is required, though more than one may be fitted.

5.5.2

Single Direction Wiring

WIRE

FROM

TO

Thick cable

Positive battery terminal

Breaker/Isolator

Thick cable

Breaker/Isolator

Solenoid

Thick cable

Solenoid

Capstan positive terminal

Thick cable

Negative battery terminal

Capstan negative terminal

Thin wire

Solenoid

Control switch(es)

Thin wire

Control switch(es)

Main circuit (positive)

Thin wire

Solenoid

Main circuit (negative)

Warning!:  If you are not sure that you understand the above guidelines seek professional advice.  NB: Use a minimum wire gauge of
1.5mm² (14 AWG) to connect switches.

Note: Reversing polarity will result in permanent damage to the capstan (see 5.2.1).  ALL installations must be carried out in accordance with

USCG, ABYC and NMMA requirements.  If you have any questions regarding this installation contact nearest Simpson-Lawrence Agent.

Содержание Pacific C1250

Страница 1: ...Additional R equirements 2 3 Electric Cable Selection 3 0 ACCESSORIES 4 0 SPECIFICATION 4 1 Performance Data 4 2 Materials 5 0 INSTALLATION 5 1 Fitting Capstan to Deck 5 2 Wiring 5 3 Test 5 4 Protection of Below Deck Parts 5 5 Wiring Diagrams 6 0 OPERATING INSTRUCTIONS 6 1 Safety First 6 2 Hauling In 7 0 IMPOR TANT USER INFOR MATION 8 0 MAINTENANCE 8 1 General R ecommendations 8 2 Winter Laying Up...

Страница 2: ... 24V Pacific C1250 Anchoring 0032020 1 2 2 Please note your serial number and voltage Printed on motor label This information is essential when ordering spares V 1 0 PAR TS 1 1 Exploded Diagram 1 2 0 For Future R eference After you have read this instruction booklet please keep it safe on board your vessel for future reference 9 11 4 2 6 5 7 15 22 16 8 17 19 25 ...

Страница 3: ...ing 1 10 P109301 Deck Clamp 1 11 P154000 Stud 6 12 P339017 Nut 6 13 P342000 O Ring 1 15 P342050 O Ring 1 16 P342435 O Ring 1 17 P354101 Screw 6 18 P354014 Screw 6 19 P354231 Screw 1 22 P366042 Washer 1 23 P366045 Washer 6 24 P418201 Gearset Complete 1 24a Gearset Complete 25 P418100 Grease Nipple 1 26 P336040HMS Motor 12V 1 26a P336041HMS Motor 24V 1 27 P118012 Pinion 1 27a Pinion 28 P303104 Sprag...

Страница 4: ...t draw imposed upon it and to keep the voltage drop within acceptable limits In any circumstance voltage drop due entirely to cable resistance should not exceed 5 roughly 0 5V for a 12V installation and 1 0V for a 24V one The following tables give recommended cable sizes The recommendations are based on the total length of cable required from the battery to the capstan and back to the battery foll...

Страница 5: ...ALL below deck surfaces including the terminals with rubber or plastic type paint automotive underseal is one convenient way OR wrap completely in self amalgamating tape OR coat protect in a similar way with some other system suitable for a marine environment 4 0 SPECIFICATION 4 1 Performance Data Typical Working Figures 12V 24V Warping Load Speed Current Draw 110kg 220lb 8 0m 26ft min 80 Amp 12V ...

Страница 6: ...witch Thick cable High load foot switch Capstan positive terminal Thick cable Negative battery terminal Capstan negative terminal 5 5 0 Wiring Diagrams 5 5 1 Single Direction Wiring High Load Foot Switch Only Note Reversing polarity will result in permanent damage to the capstan see 5 2 1 ALL installations must be carried out in accordance with USCG ABYC and NMMA requirements If you have any quest...

Страница 7: ...reaker Isolator Solenoid Thick cable Solenoid Capstan positive terminal Thick cable Negative battery terminal Capstan negative terminal Thin wire Solenoid Control switch es Thin wire Control switch es Main circuit positive Thin wire Solenoid Main circuit negative Warning If you are not sure that you understand the above guidelines seek professional advice NB Use a minimum wire gauge of 1 5mm 14 AW...

Страница 8: ...ation The speed of hauling depends on the load on the anchor and will increase after the anchor breaks free 6 2 3 Caution Should the capstan stall switch off and wait a few seconds before trying again If the recommended breaker isolator has tripped it will require to be manually reset before the capstan can operate again It is important to the future good performance of the capstan s motor that th...

Страница 9: ...well 8 0 MAINTENANCE 8 1 General Recommendations Isolate the capstan electrically before carrying out any maintenance work After the first two or three anchor recoveries check that the capstan is still fastened tightly to the deck as it should now be bedded in Every three months unscrew the drum cap top Part no 6 using a broad bladed tool As the cap may be stiff a good fit in the slot is advised t...

Страница 10: ...IONS 1 This warranty applies only if the product is used under non commercial normal use in service and shall not apply to a products subjected to i conditions or usage that exceed the product s performance specifications ii incorrect maintenance or iii use in applications for which they are not intended b defects or damage caused by a force majeure which exceed design specifications including but...

Страница 11: ...ntinual improvement Simpson Lawrence Engineering Limited reserve the right to alter specifications and recommendations without notice For the latest information regarding any aspect of your windlass please contact your local agent or Simpson Lawrence Engineering Limited ...

Страница 12: ...on lawrence co uk Service Division Telephone 44 0 141 300 9200 44 0 141 427 9666 Facsimile 44 0 141 427 5419 Simpson Lawrence USA Inc 6208 28th Street East Bradenton FLORIDA 34203 4123 United States of America Telephone 1 800 WINDLAS Toll Free 1 800 946 3527 1 941 753 7533 Facsimile 1 941 746 7166 James Nilsson Limited 69 Hillside Road Glenfield AUCKLAND 10 New Zealand Telephone 64 9 444 5219 0800...

Отзывы: