Do not drop heavy objects on hose. A sharp impact 
may cause internal damage to hose wire strands. 
Applying pressure to a damaged hose may cause it to 
rupture. 
 

IMPORTANT:

 Do not lift hydraulic equipment by the 

hose or swivel couplers. Use other means of safe 
transport. 
 

CAUTION:

 Keep hydraulic equipment away from 

flames and heat. Excessive heat will soften packing and 
seals, resulting in fluid leaks. Heat also weakens hose 
materials and packing. For optimum performance do 
not expose equipment to temperatures of 65

C (150

F) 

or higher. Protect hoses and spreaders from weld 
spatter. 
 

DANGER:

 Do not handle pressurized hoses. Escaping 

oil under pressure can penetrate the skin, causing 
serious injury. If oil is injected under the skin, see a 
doctor immediately. 
 

DANGER:

 Only use hydraulic spreaders in a coupled 

system. Never use a spreader with unconnected 
couplers. If the spreader becomes severely overloaded, 
components can fail catastrophically causing severe 
personal injury or death.  
 

 

 

3.0 SPECIFICATIONS 

 

 

 

COMPONENT S2000A 

S3000A 

MAX. 

OPERATING 
PRESSURE 

10,000 PSI  

(700kg/cm

2

)  

CAPACITY 

(TONS) 

1 0.75 

STROKE IN. 

(CM) 

3.5 

(8.89) 

11.5 (29.2) 

A. IN (CM) 

8.78 

(22.3) 

21.7 (55.0) 

B. IN (CM) 

3.70 

(9.40) 

11.5 

(29.21) 

C. IN (CM) 

0.38 

(0.97) 

1.26 

(3.20)) 

OIL CAPACITY 

0.61 in

³

 

3.91 in³ 

WEIGHT. 

5 lbs. 

25 lbs. 

MAX 

OPERATING  
TEMPERATURE 

170

 

 

4.0 INITIAL INSTALLATION

 

BEFORE OPERATING PUMP

 

 

4.1 Working Pressure 

 

The Tool’s maximum working pressure is 10,000 PSI (700kg/cm

2

). Make sure that all hydraulic equipment such as pumps, 

hoses, etc. used with this spreader are rated at 10,000 PSI (700kg/cm

2

) operating pressure, refer to the table above for 

details. 

 

 

4.2 Install Hydraulic Connections 

 

When making connections with quick disconnect couplings, make sure the couplings are fully engaged. Threaded 

connections such as fittings, gauges, etc. must be securely tightened and leak free.  Attach hose to 3/8" NPT port. 

Connect matching coupler halves together hand tight only. 

 

 

WARNING:

 Loose or improperly threaded fittings can be potentially dangerous if pressurized, however, severe over 

tightening can cause premature thread failure. Fittings need to be tightened secure & leak free. Never hold or stand 
directly in line with any hydraulic connections while pressurizing. Never grab, touch or in any way come in contact with a 
hydraulic pressure leak. Escaping oil can penetrate the skin and a serious injury can result. 

 

CAUTION:

 Do not subject the hose to potential hazards such as sharp surfaces, extreme heat or heavy impact. Do not 

allow the hose to kink or twist. Inspect each hose for wear before it is used. 
 

Содержание S2000A

Страница 1: ...om Operating Instructions Manual For 1 0 75 Ton Hydraulic Spreaders S2000A S3000A Models Reference 54486 Revison B 01 2008 Table of Contents 1 0 Receiving Instructions 2 0 Safety 3 0 Specifications 4 0 Initial Installation 5 0 Operation 6 0 Maintenance 7 0 Troubleshooting S3000A 75 Ton S2000A 1 0 Ton ...

Страница 2: ...e to comply with the following cautions and warnings could cause equipment damage property damage or personal injury CAUTION is used to indicate correct operating or maintenance procedures and practices to prevent damage to or destruction of equipment or other property WARNING indicates a potential danger that requires correct procedures or practices to avoid personal injury DANGER is only used wh...

Страница 3: ...11 5 29 21 C IN CM 0 38 0 97 1 26 3 20 OIL CAPACITY 0 61 in 3 91 in WEIGHT 5 lbs 25 lbs MAX OPERATING TEMPERATURE 170 0 F 4 0 INITIAL INSTALLATION BEFORE OPERATING PUMP 4 1 Working Pressure The Tool s maximum working pressure is 10 000 PSI 700kg cm 2 Make sure that all hydraulic equipment such as pumps hoses etc used with this spreader are rated at 10 000 PSI 700kg cm 2 operating pressure refer to...

Страница 4: ...owly or advances in spurts Oil level in pump reservoir is low Add oil according to the pump instructions Pump re lease valve open Close pump release valve Loose hydraulic coupler Check that all couplers are fully tightened Load is too heavy Do not attempt to lift more than rated tonnage Air trappedin system Remove air accordingto the instructions above Cylinder plunger binding Check for damage to ...

Отзывы: