Signal test
LED
Signal quality
flashes one time
poor
flashes two times
OK
flashes three times
Optimum
7. Hardware reset of external LockNodes
You can reset WaveNet Manager-enabled LockNodes (re-
cognisable by WN
M
in the article number):
1.
Disconnect the LockNode from the power supply or re-
move the batteries.
2. Wait for about 20 seconds.
3. Press and hold the Init button.
4. Reconnect the power supply or replace the batteries.
9
LED lights up constantly red.
5. Release the Init button while the LED is constantly red.
9
All WaveNet information in the LockNode is deleted.
You can re-integrate the LockNode into your WaveNet (see
WaveNet manual).
7. Hardware reset of external LockNodes
32 / 128 | EN
Содержание NW10.900201
Страница 2: ...deutsch 3 english 21 fran ais 38 nederlands 56 italiano 73 dansk 91 svensk 108...
Страница 12: ...4 Anschl sse antenna Direktanschluss f r SREL ADV WN KAB WI RED BF 4 Anschl sse 12 128 DE...
Страница 29: ...4 Connections antenna Direct connection for SREL ADV WN KAB WIRED BF 4 Connections 29 128 EN...
Страница 47: ...4 Raccordements antenne Raccordement direct pour SREL ADV WN KAB WI RED BF 4 Raccordements 47 128 FR...
Страница 82: ...4 Collegamenti antenna Collegamento diretto per SREL ADV WN KAB WI RED BF 4 Collegamenti 82 128 IT...
Страница 116: ...4 Anslutningar antenna Direktanslutning f r SREL ADV WN KAB WIRED BF 4 Anslutningar 116 128 SV...
Страница 125: ...11 Hj lp och ytterligare information 125 128 SV...
Страница 126: ...11 Hj lp och ytterligare information 126 128 SV...
Страница 127: ...11 Hj lp och ytterligare information 127 128 SV...
Страница 128: ......