![Simoniz VE08 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/simoniz/ve08/ve08_use-and-care-manual_1275816014.webp)
14
8. c
leanIng
and
m
aIntenance
8.1 Connections
The connections on the pressure washer’s hoses, gun, and spray
wand should be cleaned and lubricated with non-water soluble
grease regularly.
8.2 Cleaning the Nozzles
Clogging of the nozzle causes the pump pressure to be too
high, making it necessary to clean the nozzle immediately.
You can clean the nozzle by carefully inserting the cleaning
needle (H) or a thin, sharp instrument (i.e., paperclip) into the
tip to clean out any deposits.
8.3 Water Filter Screen
fig 15
The pressure washer is equipped with a water inlet screen to
protect the pump. If the screen is not kept clean, the flow of
water to the pressure washer will be restricted, and the pump
may become damaged.
To clean the water inlet screen:
•
Remove the filter screen from inside the inlet adaptor
(the inlet adaptor comes pre-assembled to the machine).
•
Rinse the screen until it is free of debris and obstructions.
•
Place the screen back to prevent foreign particles from
entering the pump.
9. t
echnIcal
s
pecIfIcatIons
Peak pressure:
1900 PSI
Rated max pressure:
1260 PSI
Power source requirement:
120 V / 60 Hz
Electrical cord:
23’ (7 m) 16 AWG
High-pressure hose:
20’ (6 m)
Max flow:
1.4 U.S. GPM (5.3 LPM)
Current drawn:
13 A
Inlet water:
Cold tap water