Description
Part No.
Key
1
238100
Strainer washer
2
10090042 Shroud Seal and Bottle release ring
NOT SHOWN:
10091920
Water inlet hose, 3/8" X 6'
10b.
TROUBLESHOOTING CHART:
Problem
Cause
Solution
1. No discharge
a. No water
a. Open water supply
b. Excessive water pressure
b. Install regulator if flowing water pressure
exceeds 80 PSI
c. Clogged water inlet strainer
c. Disconnect inlet water line and clean strainer
2. No concentrate draw
a. Low water pressure
a. Minimum 20 PSI (with water running)
required to operate unit properly
b. Concentrate container empty
b. Replace with full container
c. Concentrate container not
c. Remove and install Concentrate container
properly installed
3. Foaming in discharge
a. Concentrate container in unit
a. Remove and reinstall Concentrate container
malfunctioning or not installed
or Replace with new concentrate container
properly
4. Failure of unit to turn off
a. Excessive water pressure
a. Install regulator if pressure (with water
flowing) exceeds 80 PSI
5. Unit is too hard to turn
a. Excessive water pressure
a. Install regulator if pressure (with water
turn on
flowing) exceeds 80 PSI
1
Bottle Fill Chemical
Inlet
Bucket Fill Chemi-
cal inlet
Top view of chemical inlet port
2
Parts Diagram:
Ins
tallation & Operation continued:
4. To remove chemical concentrate container, place
hand securely under the empty product, slide release
lever to the right and pull concentrate container out.