27
Troubleshooting
IF YOU ENCOUNTER ANY ADDITIONAL DIFFICULTIES NOT LISTED, VISIT OUR WEBSITE AT
WWW.SIMONIZ.CA
OR CALL CUSTOMER SERVICE FOR HELP AT
1-866-4SIMONIZ (1-866-474-6664).
10. t
roubleShooting
(cont.)
10.3 Troubleshooting Accessories & Connections
(cont.)
Problem
Cause
Solution
Detergent is not
working.
(For use of
Foam Blaster)
Detergent container
is empty.
Add more
detergent.
Detergent bottle
or suction tube not
properly connected.
Check connections.
Detergent is too
thick.
Dilute detergent.
Damaged or clogged
detergent suction
tube.
Remove
obstruction
or replace the
detergent suction
tube.
The discharge nozzle
is obstructed.
Blow out or remove
debris with a fine
needle.
Detergent
ON/OFF
knob at
OFF
position
Set to
ON
position.
The trigger can’t
be squeezed.
Safety lock is not
open.
Open the safety
lock. Refer to the
instruction manual.
High Pressure
Hose can’t be
connected to
pump or gun.
The o-ring are not
lubricated.
Put lubricating oil
or water on the
o-ring.
XG01_3200PSI_E.indd 27
2016-12-05 4:11 PM