User manual - METER SRP-94-XC
Figure 4.3. Installing of brackets, and dimensions of connectors.
Figure 4.4. Minimum distances when assembly of a number of units
4.3.
CONNECTION METHOD
Caution
- Installation should be conducted by qualified personnel . During installation all
available safety requirements should be considered. The fitter is responsible for
executing the installation according to this manual, local safety and EMC
regulations.
- The unit is not equipped with an internal fuse or power supply circuit breaker.
Because of this an external time-delay cut-out fuse with a small nominal current
value must be used (recommended bipolar, max. 2A) and a power supply circuit-
breaker located near the unit. In the case of using a monopolar fuse it must be
mounted on the phase cable (L).
8
!
115 mm
6
7
m
m
92 mm
5 mm
12 mm
10 mm
8
,5
m
m
16
m
m