User manual - METER SRP-73-XC
- Do not use the unit in areas threatened with excessive shocks, vibrations, dust,
humidity, corrosive gasses and oils.
- Do not use the unit in areas where there is risk of explosions.
- Do not use the unit in areas with significant temperature variations, exposure to
condensation or ice.
- Do not use the unit in areas exposed to direct sunlight.
- Make sure that the ambient temperature (e.g. inside the control box) does not
exceed the recommended values. In such cases forced cooling of the unit must
be considered (e.g. by using a ventilator).
The unit is designed for operation in an industrial environment and must
not be used in a household environment or similar.
2.
GENERAL CHARACTERISTICS
meter is equipped with one voltage input 0-60 / 0-75 / 0-100 / 0-150mV.
The selection of active input is realised by software, and selected input can be changed at any
time. Additionally the
allows user to select a conversion characteristic of several
kinds: linear, square, square root, and user defined (max.20 points length). Result is showed
on 4-digit LED display. Displayed values range can be selected by user, from -999 to 9999,
plus decimal point.
The device can be equipped with one or two relay (or OC type) outputs. Device
is equipped with RS-485 / Modbus RTU communication interface and sensor supply
output. The meter can be ordered in two power supply versions.
can be used for controlling and regulation of processes need proportional
and threshold control like: temperature processes (heating or cooling), valves controlling or
other.
3.
TECHNICAL DATA
Power supply voltage
(depending on version)
External fuse (required)
Power consumption
85...
230
...260V AC/DC; 50 ÷ 60 Hz
(separated)
or 19...
24
...50V DC and 16...
24
...35V AC (separated)
T - type, max. 2 A
max. 4.5 VA @ 85 ÷ 260V AC/DC
max. 4.5 VA @ 16V ÷ 35V AC
max. 4.5 W @ 19V ÷ 50V DC
Voltage input
0÷60 mV, 0÷75 mV, 0÷100 mV, 0÷150 mV
Voltage measurement accuracy
± 0,1% @ 25°C; ± one digit (for 0÷150 mV range)
Voltage input resistance
> 100 k
W
Temperature stability
50 ppm / °C
Display range
-999 ÷ 9999, plus decimal point
Accepted prolonged input overload: 20%