![SIMES SLOT VELA S.2836 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/simes/slot-vela-s-2836/slot-vela-s-2836_installation_1275335003.webp)
For Art. S.3974 - S.3978
Direct light
for 1 lamp Metal Halide HIT-DE/High Pressure Sodium HST-DE 70W RX7s
Indirect light
for 1 lamp Metal Halide HIT-DE/High Pressure Sodium HST-DE 150W RX7s
For Art. S.3975 - S.3979
Direct light
for 1 lamp Metal Halide HIT-DE/High Pressure Sodium HST-DE 70W RX7s
Indirect light
for 1 lamp Metal Halide HIT-CRI 250W G12
N.B. : USE UV STOP LAMPS ONLY
TECHNICAL INFORMATION:
IP 65
CLASSE II
INSTALLATION INSTRUCTION:
the inspection door on bollard and let the cable comes out MIN.30 CM from the head in order to allow wiring.
Connect the supply cable (A) to the plug ( B ) ( supplied ) as follow:
1=DOWN LIGHT LINE 2= UP LIGHT LINE 3=NEUTRAL ( Pic.1 )
Open the luminaire removing rings ( C) , glasses ( D ) and top reflector( E)
Install the required lamps.
Close the luminaire reinstalling top reflector, glasses and rings.
Connect togheter the female plug ( B ) and male plug ( F )
Fit the luminaire ( G ) to the head using the supplied screws (H ).
Do not exceed the maximum wattage-see internal label
The fitting must be earthed
Disconnect the power before maintenance
Use <HAR> cable
Do not enter with single wires into the power point connector
Luminaire is suitable for installation on poles Art. S.2836 - S.2837
or on existing bollards 120mm using accessory S.2835
INSTALL THE LUMINAIRE ON THE HEAD RESPECTING THE INDICATION UP-ALTO .
NOTE:
Installation should be carried out by a suitably qualified person in accordance with good electrical practice and
the appropriate national wiring regulations.
The fitting is suitable to the mounting on normal flammable surfaces
Is very important to follow these istructions to enable the fitting to be
installed uncorrectly.Please retain for information.
MEGASLOT VELA
ISTRMEGSLOVELA REV.3 09-10
Insert the supply cable ( A ) ( Dmin=6mm Dmax=12mm ) trought the head of luminaire up to reach
RECOMMENDATIONS:
C
A
B
D
C
D
E
F
G
H
UP
ALTO
1 - DOWN LINE
2 - UP LINE
3 - NEUTRAL
The protection screen must be replaced
only with SIMES original spare parts.
The fitting must be used only with the protection
screen.