background image

Installation/Operation/Parts

For further operating, installation, 
or maintenance assistance: 

Call 1-800-468-7867

English

 . . . . . . . . . . . . .

Pages 2-11

Installation/Fonctionnement/Pièces

Pour plus de renseignements 
concernant l’utilisation,
l’installation ou l’entretien,

Composer le 1 (800) 468-7867

Français 

 . . . . . . . . . .

Pages 12-21

Instalación/Operación/Piezas

Para mayor información sobre el 
funcionamiento, instalación o 
mantenimiento de la bomba:

Llame al 1-800-468-7867

Español

 . . . . . . . . . .

Paginas 22-31

©2003. PRINTED IN U.S.A.

1000001410 (Rev. 5/20/03)

OWNER’S MANUAL

Battery Backup System

NOTICE D’UTILISATION

Système de secours à batterie

MANUAL DEL USUARIO

Systema de respaldo de la batería

ALARM RESET
SOFT RESET

AUDIBLE ALARM

DISABLE

CHARGING - 

YELLO

W

CHARGED  -   GREEN

LO

W BA

TTER

Y ALARM

AU

DIB

LE

 A

LAR

M

SILE

NCE

PU

MP

 RU

N A

LA

RM

A.C

.P

OW

ER O

N

MIC

RO

 PR

OC

ESS

OR CO

NT

ROL

LED

5 S

TAG

E B

ATT

ER

Y C

HA

RG

E/M

AIN

TA

INE

R

12  VOL

T  8  

AMP

ALW

AY

S R

EA

D W

AR

NIN

GS

 IN

 IN

ST

RU

CT

IO

N

MA

NU

AL

 BE

FO

RE

 U

SIN

G.

®

A5500

®

293 Wright St., Delavan, WI 53115

Phone:

1-800-468-7867
1-800-546-7867

Fax:

1-800-390-5351

Web Site:

http://www.simerpump.com

Содержание A5500

Страница 1: ...31 2003 PRINTED IN U S A 1000001410 Rev 5 20 03 OWNER S MANUAL Battery Backup System NOTICE D UTILISATION Système de secours à batterie MANUAL DEL USUARIO Systema de respaldo de la batería AL AR M RE SE T SO FT RE SE T AU DI BL E AL AR M DI SA BL E CH AR GIN G YE LL OW CH AR GE D GR EE N LO W BA TT ER Y AL AR M AU DI BL E AL AR M SIL EN CE PU MP RU N AL AR M A C PO WER ON MIC RO PR OC ES SO R CO N...

Страница 2: ...mended for use on any electrical appliance submerged in water 3 Use this system only for backup sump pump duty in a residential application It is not designed as a pri mary sump pump 4 Do not lift pump by electrical cord Risk of electrical shock Do not lift the pump by the electrical cord lift pump only by the dis charge pipe lifting ring or handle on the pump Lifting by the cord can damage the co...

Страница 3: ... normal application use or service including but not limited to operational fail ures caused by corrosion rust or other foreign materials in the system or oper ation at pressures in excess of recommended maximums Requests for service under this warranty shall be made by returning the defec tive product to the Retail outlet or to SIMER as soon as possible after the dis covery of any alleged defect ...

Страница 4: ...ailure to follow this warning can result in personal injury or death 3 Unplug the pump 4 To separate the primary pump from the discharge pipe A For applications with rubber couplings remove the coupling clamp with a nut driver B For applications without rubber couplings cut the PVC discharge pipe with a hacksaw above the basement floor and at a comfortable level New rubber couplings are included f...

Страница 5: ...here must be a check valve installed in the Primary Sump Pump discharge pipe between the tee and the Primary Sump Pump This will prevent recirculation into the Primary Pump when the Backup Sump Pump comes on 11 Slip a reducer bushing onto the end of the pipe com ing from the primary pump discharge Do not glue this connection yet NOTICE If your discharge pipe diameter is 1 1 4 you will need to glue...

Страница 6: ...and pump assembly 4 Thread the close nipple into the tee Key No 2 FloatSwitch TetherLength 2 5 63 5mm Tee Hose Coupling and Clamps Discharge Pipe Cable Ties 2 Minimum To the back up pump discharge pipe Short length of discharge Pipe length may vary Check valve 3546 1099 S521 Primary Sump Pump Discharge Pipe Figure 4 Back up pump float switch tether length and discharge pipe Figure 5 Method B Make ...

Страница 7: ...terfere with each other Make sure there is plenty of room for the float switch es to swing from their off to their on positions Mark and Glue Assembly 1 Mark the pipe and the fittings at all the connections with a pencil These marks will be used as a reassembly guide while gluing to be sure that every thing is still in the right place and nothing has moved 2 Loosen the rubber coupling and clamp co...

Страница 8: ...battery Positive battery terminal leads are provided Negative lead from the battery Negative battery terminal leads are provided Positive Backup sump Pump Positive pump lead terminal lead BROWN wire Negative Backup sump Pump Negative pump lead terminal lead BLACK wire Positive Float switch Lead Positive float switch terminal WHITE wire Negative Float Switch Lead Negative float switch terminal BLAC...

Страница 9: ...wo or more bad cells the battery is in a heavily discharge state 2 Yellow bicolor charging LED continuously on indicates Constant current charge stage Charger is charging battery at full rated output 3 Yellow bicolor charging LED flashing quickly indicates Constant voltage charge stage Battery cells are being equalized 4 Green bicolor charging LED indicates Float charge stage Battery terminal volt...

Страница 10: ...tact with skin eyes or clothing NOTICE To protect battery case from chipping and gouging do not let battery sit on concrete floor Install battery on a shelf or protective pad plywood 2x4s etc Always install battery in a dry location that is protected from flooding Follow the battery manufacturer s recommendations for maintenance and safe use of battery TROUBLESHOOTING Pump won t run 1 Check all wi...

Страница 11: ...U CTI ON MA NU AL BEF OR E USI NG Included in Fittings Package Includes 1 1 2 x 1 1 4 Reducer Bushings 2 Included with Key No 11 Not illustrated Purchase locally Key No Part Description A5500 1 Rubber Hose Coupling and Clamps U74 68 2 PVC Tee 1 1 2 x 1 1 2 Slip x 1 1 4 FNPTW 1 1 4 U78 846P 3 PVC Pipe Nipple 1 1 4 NPT x Close U37 66P 4 Coupling Check Valve Assembly 1 1 4 FNPT x 1 1 4 FNPT U212 261P...

Отзывы: