background image

For parts or assistance, call Simer Customer Service at 

1-800-468-7867 / 1-800-546-7867

General Information

3

GENERAL SAFETY INFORMATION

Electrically powered sump pumps normally give many
years of trouble-free service when correctly installed, main-
tained, and used. However, unusual circumstances (inter-
ruption of power to the pump, dirt/debris in the sump,
flooding that exceeds the pump’s capacity, electrical or
mechanical failure in the pump, etc.) may prevent your
pump from functioning normally. To prevent possible water
damage due to flooding, consult your dealer about
installing a secondary sump pump, a DC backup sump
pump, and/or a high water alarm. See the “Troubleshooting
Chart” in this manual for information about common sump
pump problems and remedies. For more information, see
your dealer or call customer service at 1-800-468-7867.

1. Know the pump application, limitations, and poten-

tial hazards.

2. Disconnect the power before servicing.
3. Release all pressure within the system before servic-

ing any component.

4. Drain all water from the system before servicing.
5. Secure the discharge line before starting the pump.

An unsecured discharge line will whip, possibly
causing personal injury and/or property damage.

6. Check the hoses for a weak or worn condition before

each use. Make certain all connections are secure.

7. Periodically inspect the sump, pump and system

components. Keep free of debris and foreign objects.
Perform routine maintenance as required. 

8. Provide a means of pressure relief for pumps whose

discharge line can be shut-off or obstructed.

9. Personal Safety:

a. Wear safety glasses at all times when working

with pumps.

b. Keep the work area clean, uncluttered and 

properly lighted – replace all unused tools and
equipment.

c. Keep visitors at a safe distance from work area.
d. Make the workshop child-proof – with padlocks,

master switches, and by removing starter keys.

10. When wiring an electrically driven pump, follow all

electrical and safety codes that apply.

11.

This equipment is only for use on 115 volt (single
phase) and is equipped with an approved 3-conduc-
tor cord and 3-prong, grounding-type plug.

Electrical shock hazard. Can burn or

kill.

To reduce risk of electric shock, pull plug before

servicing. Pump is supplied with a grounding con-
ductor and grounding-type attachment plug. Be sure
it is connected only to a properly grounded ground-
ing-type receptacle.

Where a 2-prong wall receptacle is encountered, it
must be replaced with a properly grounded 3-prong
receptacle installed in accordance with codes and
ordinances that apply.

This pump has not been investigated for use in
swimming pool areas.

12. All wiring should be performed by a qualified elec-

trician.

13. Make certain the power source conforms to the

requirements of your equipment.

14. Protect the electrical cord from sharp objects, hot

surfaces, oil, and chemicals. Avoid kinking the cord.
Replace or repair damaged or worn cords immedi-
ately.

15. Do not touch an operating motor. Modern motors

are designed to operate at high temperatures.

16. Do not handle the pump or pump motor with wet

hands or when standing on wet or damp surface, or
in water.

Electrical shock hazard. Can burn or kill.

If your basement has water or moisture on floor, do not
walk on wet area until all power has been turned off. If
shut-off box is in basement, call electric company or
hydro authority to shut-off service to house, or call your
local fire department for instructions. Remove pump and
repair or replace. Failure to follow this warning can
result in fatal electrical shock.

17. Vent the sewage or septic tank according to the local

codes.

18. Do not install the pump in any location classified as

hazardous by the National Electric Code, ANSI/NFPA
70-1984 or the Canadian Electrical Code.

19.

Risk of fire and explosion. Can cause

severe injury, property damage or death.

Do not use

in explosive atmospheres. Pump water only with this
pump.  

Individual

Switch Setting

Model

Motor

Full 

Branch Circuit

Cord

in inches (mm)

Number

HP

Load Amps

Required (Amps)

Length

On      

Off

2990

1/3

9.5

15

8’

14" (356)

7" (178)

2992

1/3

9.5

15

8’

9" (229)

4" (102)

2995

1/2

11.3

15

8’

14.5" (368)

7.5" (191)

2997-IV

1/2

11.3

15

8’

9" (229)

4" (102)

MOTOR, SWITCH, & CORD SPECIFICATIONS

Содержание 2990

Страница 1: ...allation Fonctionnement Pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 468 7867 Français Pages 7 11 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 1 800 468 7867 Español Paginas 12 16 2004 PRINTED IN U S A SIM624 Rev 8 12 04 293 Wright St Delavan WI 53115 Phone...

Страница 2: ...ithin five 5 years from original consumer purchase any Pre Charge water system tank shall prove to be defective it shall be repaired or replaced at SIMER s option subject to the terms and conditions set forth below General Terms and Conditions Purchaser must pay all labor and shipping charges necessary to replace product covered by this warranty This warranty shall not apply to acts of God nor sha...

Страница 3: ...t is only for use on 115 volt single phase and is equipped with an approved 3 conduc tor cord and 3 prong grounding type plug Electrical shock hazard Can burn or kill To reduce risk of electric shock pull plug before servicing Pump is supplied with a grounding con ductor and grounding type attachment plug Be sure it is connected only to a properly grounded ground ing type receptacle Where a 2 pron...

Страница 4: ...ise and vibrations a short length of rubber hose e g radiator hose can be connected into the discharge line near the pump using suitable clamps 6 Install an in line check valve to prevent backward flow through the pump when the pump shuts off 7 Power Supply The pump is designed for 115 V 60 Hz operation and requires a minimum 15 amp indi vidual branch circuit refer to Motor Switch and Cord Specifi...

Страница 5: ...broken prime Float Switch Tether Length Models 2990 and 2995 NOTICE Do not change the tether length of the float switch The float must be able to swing through its com plete arc without interference For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867 Troubleshooting 4 1 4 to 4 3 4 108 to 121 mm SYMPTOM PROBABLE CAUSE S CORRECTIVE ACTION Pump won t start Blown fuse ...

Страница 6: ... 7 Retainer Power Cord 2 854 349 B 854 349 B 854 349 B 854 349 B 8 Screw Handle Ring 1 9 Lock Washer Handle Ring 1 854 142 854 142 854 142 854 142 10 Handle Ring 1 383 148 383 148 383 148 383 148 11 Clamp Handle Ring 1 188 043 188 043 188 043 188 043 12 Motor Cover Motor 1 13A Impeller 1 991 594 B 991 594 B 13B Impeller 1 416 037 416 037 14A Volute 1 992 798 B 992 798 B 14B Volute 1 991 273 B 991 ...

Страница 7: ... dans les douze 12 mois qui suivent la date d achat d origine sera remplacé ou réparé à la discrétion de SIMER selon les con ditions stipulées ci dessous La preuve datée de l achat servira à déterminer si le produit est sous garantie Exceptions à la garantie de douze 12 mois Garantie de cinq 5 ans Si dans les cinq 5 ans à compter de la date de son achat par l Acheteur un réser voir de système d ea...

Страница 8: ...ranche une électropompe sur le courant élec trique toujours respecter les codes de l électricité et de la sécurité en vigueur 11 Cette pompe ne fonctionne que sur le courant alternatif monophasé de 115 volts Elle est livrée avec un cordon électrique à 3 conducteurs muni d une fiche à 3 broches dont une de mise à la terre Risque de secousses électriques de brûlures voire de mort Pour réduire les ri...

Страница 9: ...ur un petit morceau de tuyau souple en caoutchouc une durite de radiateur par exemple pourra être branché sur le tuyau de refoulement près de la pompe Faire tenir ce petit morceau de tuyau en caoutchouc souple avec des colliers 6 Poser un clapet de non retour en ligne pour empêcher que le liquide pompé retourne dans la pompe lorsqu elle s ar rêtera de fonctionner 7 Courant électrique Cette pompe e...

Страница 10: ...ur des modèles 29990 et 2995 NOTA Ne pas modifier la longueur du cordon électrique de l interrupteur à flotteur L interrupteur à flotteur doit toujours pouvoir se déplacer sur un arc complet sans être gêné Pour obtenir des pièces ou de l aide appeler le Service à la clientèle Simer en composant le 1 800 468 7867 1 800 546 7867 Recherche des pannes 4 1 4 to 4 3 4 108 to 121 mm SYMPTÔMES CAUSES POSS...

Страница 11: ...ique 2 854 349 B 854 349 B 854 349 B 854 349 B 8 Vis de l anneau de transport 1 9 Rondelle frein de l anneau de transport 1 854 142 854 142 854 142 854 142 10 Anneau de transport 1 383 148 383 148 383 148 383 148 11 Collier de l anneau de transport 1 188 043 188 043 188 043 188 043 12 Couvercle du moteur et moteur 1 13A Impulseur 1 991 594 B 991 594 B 13B Impulseur 1 416 037 416 037 14A Volute 1 9...

Страница 12: ...o reemplazado a opción de SIMER sujeto a los términos y condiciones mencionados a continuación Su recibo de compra se usará para determinar la elegibilidad de la garantía Excepciones a la Garantía de doce 12 meses Garantía de cinco 5 años Si dentro de los cinco 5 años desde la compra original por el consumidor de cualquier tanque para un sistema hidráulico de pre carga éste resulta defectuoso será...

Страница 13: ...ódigos eléctricos y de seguridad que correspondan 11 Esta bomba se puede usar solamente con corriente de 115 voltios monofásica y está equipada con un cordón aprobado de 3 conductores y 3 clavijas de tipo con conexión a tierra Riesgo de choque eléctrico Puede causar quemaduras o muerte Para reducir el riesgo de choque eléctrico desenchufe la bomba antes de reparar la La bomba es suministrada con u...

Страница 14: ... bomba usando las abrazaderas adecuadas 6 Instale una válvula de retención en línea para evitar el retroflujo a través de la bomba cuando ésta se apague 7 Fuente de Alimentación La bomba está diseñada para funcionar con corriente de 115 V 60 Hz y requiere un ramal individual mínimo de 15 amps Consulte la tabla de Especificaciones del motor conmutador y cordón en la página 1 Tanto la bomba como el ...

Страница 15: ...250120T AVISO No cambie el largo de la traba del conmutador de flotación El flotador debe poder columpiarse en su arco com pleto sin interfieran ADVERTENCIA ADVERTENCIA Si necesita repuestos o asistencia llame al Servicio al Cliente de Simer 1 800 468 7867 1 800 546 7867 Localización de fallas 4 1 4 to 4 3 4 108 to 121 mm SÍNTOMA CAUSA S PROBABLE S ACCIÓN CORRECTIVA La bomba no arranca Fusible que...

Страница 16: ...ctrico 2 854 349 B 854 349 B 854 349 B 854 349 B 8 Tornillo mango anular 1 9 Arandela de seguridad mango anular 1 854 142 854 142 854 142 854 142 10 Mango anular 1 383 148 383 148 383 148 383 148 11 Abrazadera mango anular 1 188 043 188 043 188 043 188 043 12 Cubierta del motor Motor 1 13A Impulsor 1 991 594 B 991 594 B 13B Impulsor 1 416 037 416 037 14A Voluta 1 992 798 B 992 798 B 14B Voluta 1 9...

Отзывы: