For parts or assistance, call Simer Customer Service at
1-800-468-7867 / 1-800-546-7867
General Information
3
GENERAL SAFETY INFORMATION
Electrically powered sump pumps normally give many
years of trouble-free service when correctly installed, main-
tained, and used. However, unusual circumstances (inter-
ruption of power to the pump, dirt/debris in the sump,
flooding that exceeds the pump’s capacity, electrical or
mechanical failure in the pump, etc.) may prevent your
pump from functioning normally. To prevent possible water
damage due to flooding, consult your dealer about
installing a secondary sump pump, a DC backup sump
pump, and/or a high water alarm. See the “Troubleshooting
Chart” in this manual for information about common sump
pump problems and remedies. For more information, see
your dealer or call customer service at 1-800-468-7867.
1. Know the pump application, limitations, and poten-
tial hazards.
2. Disconnect the power before servicing.
3. Release all pressure within the system before servic-
ing any component.
4. Drain all water from the system before servicing.
5. Secure the discharge line before starting the pump.
An unsecured discharge line will whip, possibly
causing personal injury and/or property damage.
6. Check the hoses for a weak or worn condition before
each use. Make certain all connections are secure.
7. Periodically inspect the sump, pump and system
components. Keep free of debris and foreign objects.
Perform routine maintenance as required.
8. Provide a means of pressure relief for pumps whose
discharge line can be shut-off or obstructed.
9. Personal Safety:
a. Wear safety glasses at all times when working
with pumps.
b. Keep the work area clean, uncluttered and
properly lighted – replace all unused tools and
equipment.
c. Keep visitors at a safe distance from work area.
d. Make the workshop child-proof – with padlocks,
master switches, and by removing starter keys.
10. When wiring an electrically driven pump, follow all
electrical and safety codes that apply.
11.
This equipment is only for use on 115 volt (single
phase) and is equipped with an approved 3-conduc-
tor cord and 3-prong, grounding-type plug.
Electrical shock hazard. Can burn or
kill.
To reduce risk of electric shock, pull plug before
servicing. Pump is supplied with a grounding con-
ductor and grounding-type attachment plug. Be sure
it is connected only to a properly grounded ground-
ing-type receptacle.
Where a 2-prong wall receptacle is encountered, it
must be replaced with a properly grounded 3-prong
receptacle installed in accordance with codes and
ordinances that apply.
This pump has not been investigated for use in
swimming pool areas.
12. All wiring should be performed by a qualified elec-
trician.
13. Make certain the power source conforms to the
requirements of your equipment.
14. Protect the electrical cord from sharp objects, hot
surfaces, oil, and chemicals. Avoid kinking the cord.
Replace or repair damaged or worn cords immedi-
ately.
15. Do not touch an operating motor. Modern motors
are designed to operate at high temperatures.
16. Do not handle the pump or pump motor with wet
hands or when standing on wet or damp surface, or
in water.
Electrical shock hazard. Can burn or kill.
If your basement has water or moisture on floor, do not
walk on wet area until all power has been turned off. If
shut-off box is in basement, call electric company or
hydro authority to shut-off service to house, or call your
local fire department for instructions. Remove pump and
repair or replace. Failure to follow this warning can
result in fatal electrical shock.
17. Vent the sewage or septic tank according to the local
codes.
18. Do not install the pump in any location classified as
hazardous by the National Electric Code, ANSI/NFPA
70-1984 or the Canadian Electrical Code.
19.
Risk of fire and explosion. Can cause
severe injury, property damage or death.
Do not use
in explosive atmospheres. Pump water only with this
pump.
Individual
Switch Setting
Model
Motor
Full
Branch Circuit
Cord
in inches (mm)
Number
HP
Load Amps
Required (Amps)
Length
On
Off
2990
1/3
9.5
15
8’
14" (356)
7" (178)
2992
1/3
9.5
15
8’
9" (229)
4" (102)
2995
1/2
11.3
15
8’
14.5" (368)
7.5" (191)
2997-IV
1/2
11.3
15
8’
9" (229)
4" (102)
MOTOR, SWITCH, & CORD SPECIFICATIONS