Supplied By www.heating spares.co Tel. 0161 620 6677
3
40 Ci
50 Ci
60 Ci
80 Ci
Burner
Injector
1
ø mm
3.25
3.25
3.55
4.10
Max. gas consumpt.
m
3
/h
1,38
1,69
2,05
2,75
System Press
min
bar
0.12
0.12
0.12
0.12
max
bar
3
3
3
3
Adjustable Flow Temp
Pump mode min
°C
50 on - 60 off
Pump mode max °C
72 on - 84 off
Safety stat
°C
105
105
105
105
Re-Start Delay
Seconds
180
180
180
180
Anti-Inertia Temp.
°C
90 off - 95 on
Max. working temp.
°C
84
84
84
84
Boiler pressure drop
∆
t 11°C
mbar
100
150
220
330
Electricity Supply
230V/50Hz
Internal Fuse
F 2A
Power Consumption
W
55
55
60
65
Weight
kg
46
46
46
57
TABLE 4 - General specifications
17
3
4
6
7
1
8
5
2
9
16
10
11
12
13
14
15
1.4
INTERNAL VIEW
KEY
1 Air pressure switch
2 Safety stat 105°C
3 Positive pressure test point
4 Negative pressure test point
5 Thermistor
6 Fan
7 Cast-iron heat exchanger
8 Ignition electrode/ionisation probe
9 Main burner assembly
10 Terminal strip
11 On/Off switch - Potentiometer
12 Lock-out button
13 Gas valve
14 Control box
15 Main gas nozzle
16 Gas cock
17 Pumped/gravity switch
Fig. 2