46
– turn the
encoder to select the
“Climatic curve ”
row
Zone heating
Esc
BACK
Req. from ext. TA
NO
Room probe run
YES
Room probe modul.
YES
Ext. probe modul.
YES
Weather comp.curve
4.0
Fig. 77
– press the
encoder to confirm the highlighted “Row”
and access the modifiable parameters.
Zone heating
Esc
BACK
Req. from ext. TA
NO
Room probe run
YES
Room probe modul.
YES
Ext. probe modul.
YES
Weather comp.curve
4.0
Fig. 78
– turn the
encoder to select the
preferred climatic curve
(from 1 to 9) according to the system requirements
– press the
encoder to confirm the selection
– press the
Esc
button to go back to the “Main screen”.
m
CAUTION
The submenu
“Hybrid func. status”
is read-only.
5.14.2 Chrono-thermostat or room thermostat for
the zone
The chrono-thermostat or room thermostat for the zone must
be connected to terminals AT2 on the boiler control panel (gas
side).
To set the MULTIZONE system configuration, operate the main
control panel as described below.
From the
“Main screen”
:
Thu 18 Set 2014
Zone
10:30
Menu
Mode
Off
Fig. 79
– press the
Mode
button to access the
“Function mode”
select screen
– turn the
encoder to select
"Winter"
mode
Esc
Back
Winter
Off
Summer
Hot water
MAN 40°C
Heating
MAN 20.0°C
Holiday function OFF
Fig. 80
– press the
click
encoder to confirm and access the
“Rows”
– turn the
encoder to select
“Heating”
– press the
encoder to confirm
“Heating”
and access the
“Rows”
Esc
Back
Winter
Off
Summer
Hot water
MAN 40°C
Heating
MAN 20.0°C
Holiday function OFF
Fig. 81
– turn the
encoder to select
“Function mode”
– press the
click
encoder to confirm the
“Function mode”
and
go to the modifiable area
Esc
Back
Heating
Function Mode
MAN
Set AUTO comfort
20.0°C
Set AUTO reduced
18.0°C
Set MAN
20.0°C
Program. Time
[...]
Fig. 82
– turn the
encoder to select
“OFF”
– press the
click
encoder to confirm
Esc
Back
Heating
Function Mode
MAN
Set AUTO comfort
20.0°C
Set AUTO reduced
18.0°C
Set MAN
20.0°C
Program. Time
[...]
Fig. 83
– press the
Esc
button to complete the modification
and return to the
“Main screen”
.