Sime Murelle Pro 25 LPG Скачать руководство пользователя страница 44

44

Pos.

Code Description

Murelle Pro

25 LPG

1

6264560 Boiler fixing bracket

x

2

6317601 Sealed chamber rear panel

x

3

6229838 Gasket for sealed chamber

x

4

5183728 Rectang. expansion vessel 8 l. 3/8" M

x

5

6257531 Air deflector

x

6

5198211 Main burner assembly

x

7

6235935 Ignition-ionisation electrode

x

8

6318520 Smoke chamber assembly

x

9

6318740 Combustion chamber rear insulation

x

10 6318710 Combustion chamber side insulation

x

11 6174275 Gas/Water heat exchanger

x

12 6231362 NTC sensor

x

13 6318600 Sealed chamber front panel

x

14 6225643 Fan

x

15 6317900 Combustion chamber front panel

x

16 6318730 Combustion chamber side insulation

x

17 6264863 C.H. return pipe

x

18 6226412 O-ring 3068

x

19 6226601 Spring for heat exchanger connection

x

20 6227458 Flowing pipe to C.H. system

x

21 6288210 Sealed chamber side panel

x

22 6229837 Gasket for sealed chamber

x

23 6146101 Hydrometer

x

24 6037510 Water pressure switch

x

25 6226639 Spring clip

x

26 2030267 Piracriten gasket Ø 30x17x2

x

27 6226628 Hydrometer Fixing spring

x

28 6017405 Flexible pipe M.F. 3/8" L=300

x

29 6226476 ORing diam.15x2

x

30 6226643 Pipe fixing spring

x

31 2030226 Gasket Ø 10,2x14,8x2

x

32 6243838 Gas valve

x

33 2030249 Gasket Ø 24x17x3

x

34 6195216 Gas inlet pipe

x

35 2030255 Gasket Ø 12,5x18,5x3

x

36 6226638 Divertor valve motor spring clip

x

37 6317700 Sealed chamber front panel

x

38 5192208 Gasket for sealed chamber

x

39 6304480 casing left/right side panel

x

40 6325050 Front panel

x

41 6028621 Air diaphragm Ø 79

x

42 6022004 Copper washer Ø 6

x

43 6154406 Main burner nozzle NP 0,80

x

44 6175180 Flow control spacer

x

45 2030228 Gasket Ø 17x24x2

x

46 6120560 Pump nipple 3/4"

x

47 6226644 Spring clip for rotating connection

x

48 6226475 ORing diam.18,64x3,53

x

49 6272340 Circulating pump

x

50 6013182 Automatic air vent

x

51 6245000 Ball cock 3/4"x22

x

52 6222003 D.H.W. filter

x

53 6265830 C.H. return manifold

x

54 6040211 Pressure relief valve 3 bar

x

55 6226626 Pipe fixing spring

x

56 6131440 Flowmeter sensor

x

57 6231351 Plunged sensor

x

58 6265871 C.H. flow manifold

x

59 6226636 D.H.W. elektrovalve fix.spring

x

Pos.

Code Description

Murelle Pro

25 LPG

60 6087332 Motor for diverting valve

x

61 6063602 Gas cock 3/4X1/2F

x

62 6265655 10 plate-type heat exchanger

x

63 6319643 Discharger cock

x

64 6147231 Straight fitting 1/2" Ø 15

x

65 6281430 12 l/min. flow control

x

67 2030227 Gasket Ø 12x18x2

x

68 6245001 Ball cock 1/2"x15

x

69 6157653 Pressure relief valve drain pipe

x

70 6304720 Control panel

x

71 6324910 Main P.C.B.

x

72 6305130 Rubber button

x

73 6304830 Interface panel

x

74 6290150 Knob Ø 25

x

75 6305140 Rubber cap

x

76 6245374 Circulating pump connector

x

77 6319644 Flowmeter group

x

78 6319645 Three-way plates group

x

79 6197719 Time programmer

x

83 6275910 Pressure relief valve operation lever

x

84 6301461 Programmer clock expansion board

x

85 6247370 Cap for programmer clock

x

700 6281534 Gaskets kit

x

701 6319695 Murelle-Format-.....o-ring kit

x

703 5185403 Convers. kit to nat. gas 25-30-35 kW

x

704 5202320 Complete control panel

x

705 6323875 6 pole cable connector

x

706 6323876 4 pole cable connector

x

707 6323878 9 pole cable connector

x

708 6323879 4 pole cable connector

x

710 6319700 Springs / clamps kit DIN

x

711 6325608 14 pole cable connector

x

Содержание Murelle Pro 25 LPG

Страница 1: ...R THE USER AFTER COMPLETION OF THE BENCHMARK SECTION PLEASE READ THE IMPORTANT NOTICE WITHIN THIS GUIDE REGARDING YOUR BOILER WARRANTY Cod 6316191 08 2013 BRAVA DGT HE 25 30 35 199838 INSTALLATION AND...

Страница 2: ...Use a suitable container to catch any water that escape when removing the protective caps from the connections All descriptions and illustrations provided in this manual have been carefully prepared...

Страница 3: ...3...

Страница 4: ...hat the installer has fully completed the Benchmark Checklist in the use and maintenance section of the installation instructions supplied with the product and that you have signed it to say that you...

Страница 5: ...iances such as switches electrical appliances etc if you can smell gas If this should happen open the doors and windows to air the room close the gas isolation device seek help from a qualified engine...

Страница 6: ...ectives Gas Appliances Directive 2009 142 EC Boiler Efficiency Directive 92 42 EEC Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC Manual structure This manual is...

Страница 7: ...ALLING ON 0800 408 5500 OR ALTERNATIVELY WWW GASSAFEREGISTER CO UK 1 Operating the Murelle Pro 25 LPG 8 1 1 Control panel 8 1 2 Preliminary checks 8 1 3 Ignition 9 1 4 Adjusting the delivery temperatu...

Страница 8: ...Winter mode or if both the domestic hot water and heating modes are enabled via the remote control With dedicated remote controls CR or Home if no operating modes have been enabled both symbols l and...

Страница 9: ...1 4 Adjusting the delivery temperature The temperature of the heating water can be adjusted by turning the t knob on the control panel Fig 3 1 5 Adjusting the domestic hot water temperature The temper...

Страница 10: ...s cock close the heating and domestic hot water isolation valves drain the heating and domestic hot water system if there is the risk of freezing m CAUTION Special attention should be made to installa...

Страница 11: ...e appliance 12 5 1 Characteristics 12 5 2 Check and safety devices 12 5 3 Identification 12 5 4 Structure 13 5 5 Technical features 14 5 6 Main water circuit 15 5 7 Sensors 15 5 8 Expansion vessel 15...

Страница 12: ...he chimney sweep function lasts 15 minutes and makes the job of the qualified technician easier when measuring the parameters and combustion efficiency and when checking gas pressure at the nozzles sc...

Страница 13: ...detection electrode 5 Diverter valve 6 Domestic hot water sensor SS 7 Control panel 8 Secondary heat exchanger 9 Gas valve 10 Domestic water filter and flow regulator 11 System relief valve 12 Boiler...

Страница 14: ...ontinuous D H W flow rate t 25 C t 35 C l min 13 6 9 7 Minimum D H W flow rate l min 2 2 Max Min Pressure bar 7 0 4 kpa 700 40 Electrical specifications Power supply voltage V 230 Frequency Hz 50 Abso...

Страница 15: ...2164 1622 1232 25044 16563 11199 7731 5440 3897 2839 2101 1577 1199 24004 15912 10781 7458 5258 3773 2753 2040 1534 1168 23014 15289 10382 7196 5082 3653 2669 1982 1491 1137 22069 14694 9999 6944 491...

Страница 16: ...es a fault on the display without preventing boiler operation The warning disappears when the button is released 3 DISPLAY l SUMMER This symbol appears when the boiler is operating in Summer mode or i...

Страница 17: ...nal sensor CR Remote control instead of room thermostat OP Mechanical timer Note Volt free external controls TA are connected to terminals 5 and 6 after removal of the link Fig 11 m CAUTION Installer...

Страница 18: ...tions by competent persons and that it meets the require ments of the appropriate Building Regulations The Benchmark Checklist can be used to demonstrate compliance with Building Regulations and shoul...

Страница 19: ...6 9 Plumbing connections 22 6 10 Gas supply 22 6 11 Connecting the flue 23 6 11 1 Flue Terminal Positions 23 6 11 2 Installation of coaxial flues 60 100mm 80 125mm 24 6 12 Electrical connections and...

Страница 20: ...W mm 400 D mm 250 H mm 700 Weight kg 29 6 3 Handling Once the packaging has been removed the appliance is to be handled manually tilting it slightly lifting it and applying pressure in the points ind...

Страница 21: ...accumulates within the system risking damage to pump and valves boiler noise and circulation problems Before connecting the boiler the associated central heating system must be flushed in accordance...

Страница 22: ...ave the factory prearranged for gas G31 The gas connection must be made using seamless steel or copper tube Where the piping has to pass through walls a suitable insulating sleeve must be provided Whe...

Страница 23: ...be protected by a purpose designed guard The air inlet outlet flue duct MUST NOT be closer than 10 mm 0 4 in to combustible material In certain weather conditions the terminal may emit a plume of ste...

Страница 24: ...the gaskets with silicon products Avoid using oils and greases V Vertical m LIST OF 60 100 ACCESSORIES 1 Coaxial duct kit L 790 code 8084811 2a Extension L 1000 code 8096103 2b Extension L 500 code 8...

Страница 25: ...nd maintain this boiler The installation of this boiler must be in accordance with the relevant requirements of the current Gas Safety installation and use the local building regulations and I E E wir...

Страница 26: ...he building follow the instructions provided on the packaging of the product itself Climatic curve Delivery temperature 20 15 10 5 0 10 15 5 20 80 90 70 60 50 40 30 20 C C K 9 K 6 K 4 5 K 3 K 2 2 K 1...

Страница 27: ...ease it from the top by lifting it 1 2 Fig 30 Domestic hot water circuit open the domestic hot water inlet isolation valve 4 open each of the DHW taps until air is expelled Heating circuit open the is...

Страница 28: ...ircuit close the domestic hot water circuit isolation valve 4 open one or more than one hot water taps and drain the domestic hot water circuit Boiler loosen the automatic bleed valve 3 close the heat...

Страница 29: ...than 3 seconds This operation can be carried out no more than 6 times close the taps opened previously and check that the appliance shuts down press the button s once to select WINTER mode n The value...

Страница 30: ...Heating Temperature Adjustment Par tS 1 3 80 C 1 80 tS 1 5 Maximum power in CH mode 0 100 1 100 tS 1 6 Heating Post Circulation Time 0 99 seconds x 10 1 3 tS 1 7 Heating Pump Activation Delay 0 60 sec...

Страница 31: ...rrect positioning of the delivery sensor AL 74 Fault in the 2nd element of the delivery sensor AL 80 Anomaly in gas valve control line AL 81 Lockout due combustion during start up AL 83 Irregular comb...

Страница 32: ...alarm fault 7 7 Checks and adjustments 7 7 1 Chimney sweep function The chimney sweeper function is used by the qualified maintenance technician to check the gas pressure at the nozzles detect the com...

Страница 33: ...he adjustments described below must be carried out in sequence Adjusting maximum gas pressure turn the domestic hot water knob as far as it will go r press and hold down the buttons o and s at the sam...

Страница 34: ...ately 5 seconds at the same time until tS installer appears on the 2 digits of the display which alternate with 0 1 parameter number and a 1 set value NOTE holding the buttons or increases the speed o...

Страница 35: ...imum gas pressure press the button o twice the message P00 will appear on the display press the buttons or until the pressure value indicated in the table appears on the pressure gauge once the value...

Страница 36: ...nce with the relevant requirements of the current Gas Safety installation and use the local building regulations and I E E wiring regulations a DANGER Before carrying out any interventions described i...

Страница 37: ...e front panel 6 of the combustion chamber and the gasket 13 of the front panel 4 of the sealed chamber are all integral If they are not replace them refit the panels 6 and 4 securing them with fasteni...

Страница 38: ...lue exhaust blockage Check for blockage in flue Frequent relief valve intervention Check circuit pressure Check expansion vessel Limited production of domestic hot water Check the diverter valve Check...

Страница 39: ...rate m hr OR ft hr r a b m e t a r m u m i x a m t a e r u s s e r p g n i t a r e p o r e n r u B OR r a b m e t a r m u m i x a m t a e r u s s e r p t e l n i s a G Cold water inlet temperature C...

Страница 40: ...Record At max rate CO ppm AND CO At min rate Where Possible CO ppm AND CO Comments Signature SERVICE 04 Date Engineer name Company name Telephone No Gas safe register No Record At max rate CO ppm AND...

Страница 41: ...41 9 Exploded views...

Страница 42: ...42...

Страница 43: ...43...

Страница 44: ...6154406 Main burner nozzle NP 0 80 x 44 6175180 Flow control spacer x 45 2030228 Gasket 17x24x2 x 46 6120560 Pump nipple 3 4 x 47 6226644 Spring clip for rotating connection x 48 6226475 ORing diam 1...

Страница 45: ...45...

Страница 46: ...46...

Страница 47: ...47...

Страница 48: ...Sime Ltd 1a Blue Ridge Park Thunderhead Ridge Glasshoughton Castleford WF10 4UA Phone 0845 9011114 Fax 0845 9011115 www sime co uk Email enquiries sime co uk...

Отзывы: