3.4
EXTERNAL
SENSOR
(fig. 15)
If. there. is. an. external. sensor,. the. heating.
settings.SET.can.be.taken.from.the.climatic.
curves.according.to.the.external.temperatu-
re.and,.in.any.case,.limited.to.with.the.range.
values. described. in. point. 3.3. (parameters.
PAR.25.for.zone.1.and.PAR.26.for.zone.2).
The.climatic.curve.to.be.set.can.be.selected.
from.a.value.of.3.and.40.(at.step.1).
Increasing. the. steepness. of. the. curves. of.
fig..15.will.increase.the.output.temperature.
as.the.external.temperature.decreases.
3.5
CARD
FUNCTIONING
The. electronic. card. has. the. following. fun-
ctions:
–. Antifreeze. protection. of. the. heating. and.
sanitary.water.circuits.(ICE).
–. Ignition.and.flame.detection.system.
–. Control.panel.setting.for.the.power.and.
the.gas.for.boiler.functioning.
–. Anti-block.for.the.pump.which.is.fed.for.a.
few.seconds.after.24.hours.of.inactivity.
–. Antifreeze.protection.for.boilers.with.an.
accumulation.boiling.unit.
–. Chimney. sweep. function. which. can. be.
activated.from.the.control.panel.
–. Temperature. which. can. be. shifted. with.
the.external.sensor.connected..
. It.can.be.set.from.the.control.panel.and.
is.active.on.the.heating.systems.of.both.
circuit.1.and.circuit.2.
–. Management.of.two.independent.heating.
circuit.systems.
–. Automatic.regulation.of.the.ignition.power.
and.maximum.heating...Adjustments.are.
managed.automatically.by.the.electronic.
card.to.guarantee.maximum.flexibility.in.
use.of.the.system.
–. Interface. with. the. following. electronic.
systems:. remote. control. SIME.HOME.
code.8092280/81,.thermal.regulator.RVS,.
connected. to. a. management. card. of. a.
mixed.zone.ZONA.MIX.code.8092234.and.
card.solar.INSOL.code.8092235...
. NOTE: If using CR 53 or RVS set parame-
ter 10 to 2 or 3 (PAR 10 = 2 or 3).
–. Function.anticondensig,.preheat.the.body.
(“+”.sign.in.front.of.the.main.digits).and.
anti.inertia.
3.6
TEMPERATURE
DETECTION SENSOR
Table 3. gives. the. values. of. the. electrical.
element. (
Ω
). obtained. on. the. heating. and.
sanitary. water. sensors. according. to. the.
variations.in.temperature..
When the heating sensor (SM) is interrup-
ted, the boiler will not function for both
services.
With the D.H.W. sensor (SS) interrupted,
the boiler functions but will not made the
power modulations for the D.H.W.
3.7
ELECTRONIC IGNITION
Ignition.and.flame.detection.is.controlled.by.
a.single.electrode.on.the.burner.which.gua-
rantees. reaction. in. the. case. of. accidental.
extinction.or.lack.of.gas.within.one.second.
3.7.1
Functioning cycle
Burner. ignition. occurs. within. max.. 10.
seconds.after.the.opening.of.the.gas.valve..
Ignition.failure.with.consequent.activation.of.
block.can.be.due.to:
–. Lack of gas
The.ignition.electrode.persists.in.dischar-
ging. for. max.. 10. seconds.. If. the. burner.
does.not.ignite,.the.anomaly.is.signalled.
. This.can.happen.the.first.time.the.boiler.
is.switched.on.after.a.long.period.of.inac-
tivity.due.to.the.presence.of.air.in.the.gas.
pipes.
..
It.can.be.caused.by.a.closed.gas.tap.or.by.
a.broken.valve.coil.(the.interruption.does.
not.allow.for.opening)..
–. The electrode does not discharge.
. In.the.boiler,.only.the.opening.of.the.gas.
to. the. burner. can. be. detected.. After. 10.
seconds.the.anomaly.is.signalled.
.. It. can. be. caused. by. an. interruption. in.
the. electrode. wire. or. if. it. is. incorrectly.
anchored.to.the.connection.points..
. Or.the.electrode.may.be.earthed.or.stron-
gly.worn:.it.must.be.replaced..
. Or.the.electronic.card.may.be.defective.
In.the.case.of.a.sudden.lack.of.voltage,.the.
burner. will. immediately. switch. off.. When.
voltage.returns,.the.boiler.will.automatically.
start.up.again.
3.8
FUMES THERMOSTAT
This.is.a.safety.measure.against.the.return.
of. the. fumes. into. the. environment. due. to.
an. inefficient. or. partially. blocked. chimney.
(6.fig..3)..
It. reacts.by. blocking. the. functioning.of. the.
TABLE 3
. Temperature.(°C).
Resistance.(Ω)
.
20.
12.090
.
30.
8.313
.
40.
5.828
.
50.
4.161
.
60.
3.021
.
70.
2.229
.
80.
1.669
Fig..15
ATTENTION: curves are calculated at an ambient
temperature of 20°C. The user can act on the boiler
controls to change the environment set for which the
bend has been calculated by ±5°C.
Содержание Murelle 25 OF
Страница 1: ...MURELLE 25 30 OF ErP Fonderie SIME S p A Cod 6322862A 03 2017 ES PT ENG...
Страница 2: ......
Страница 35: ......