20
– To gain access to connector
“TA”
, remove the control
panel cover (7) and connect the room stat to the
terminals 10-11 after having removed the jumper.
The thermostat or timer-thermostat, recommended for
better room temperature control, must be class II as
specified by standard EN 60730.1 (clean contact).
– Carry out electrical system checks through a suitable test
meter: earth continuity, polarity, resistance to earth and
short circuit.
– Re-secure control box.
– Ensure sufficient length of cable to allow access to control
panel.
8
1
2
5
4
7
6
Fig. 20
KEY
1
Temperature and pressure gauge
2
Easy-Stat Receiver housing (8092221)
4
Main PCB
5
Earth faston
6
Control panel protection
7
Cover (TA)
8
Connector (TA)
ATTENTION: After having removed the three fixing
screws, tilt the panel downward to gain access.
Содержание Format B