empty the water in the boiler (see
section 8.6);
unscrew the top anode and check for
any corrosion; if more than 30% of the
anode surface is corroded, replace the
anode;
repeat for the bottom anode.
The anodes have a gasket; to avoid water
leakages, use an anaerobic sealant for
compatible threads for use in heating and
sanitation systems. The gaskets should be
replaced both during checks and when
replacing anodes with new gaskets.
8.6
Emptying the boiler
If the boiler is not used, especially in low
temperatures, it is good practice to empty
the water inside the boiler.
For this appliance, simply disconnect the
water inlet connector (see section 5.4).
Alternatively, when setting up the system,
install a drain valve with a hose connector
coupling.
NOTE: remember to empty the
system when temperatures are
low to prevent freezing.
9
Faults
Should you notice anything unusual as
regards appliance operation, without there
being an alarm or error code as described
in the relevant parts of this manual, check
whether the problem is easily resolvable by
consulting
the
table
below,
before
contacting technical support.
Fault
Possible causes
The heat pump does
not turn on
There
is
no
electricity;
The plug is not
plugged into the
socket properly
The compressor or
fan
are
not
activated
The pre-set safety
time has not passed
yet
The
programmed
temperature
has
been reached
The heat pump is
activated
and
deactivated
repeatedly
Incorrect
programming
of
parameters/ setpoint
values/ differentials
The
heat
pump
remains active and
never switches off
Incorrect
programming
of
parameters/ setpoint
values/ differentials
The electrical resistor
does not turn on
It does not need to
turn on
WARNING: should you not be
able to solve the problem, turn
the appliance off and contact
the technical support service,
specifying the appliance model
you have purchased.
10
Disposal
At the end of their life, the heat pumps
should be disposed of in line with the
regulations in force.
WARNING:
this
appliance
contains fluorinated greenhouse
gases included under the Kyoto
Protocol.
Maintenance
and
disposal must only be carried out
by qualified personnel.